Ricoh Aficio MP171 Field Service Manual page 210

Hide thumbs Also See for Aficio MP171:
Table of Contents

Advertisement

3. Appendices: SP Mode Tables
5067
5-067-001 PCDU
5-067-009 Fusing Unit
5083
5-083-001 Toner Near End
5302
5-302-002 Time Difference
5305
RTB 18
5-305-101 Set Disp
42
[Parts PM System]
Selects the whether to perform the service management or user management as the
PM management. The system banner and the message in which the system warning
screen appears varies according to this setting.
[Led Switch]
Specifies whether the alert LED is lit or not when toner near end condition is
detected. (This does not change the toner near end condition indication in the
operation panel LCD.)
[Set Time]
Adjusts the RTC (real time clock) time setting for the local time zone.
Examples: For Japan (+9 GMT), enter 540 (9 hours x 60 min.)
JP: +540 (Tokyo)
NA: -300 (New York)
EU: + 60 (Paris)
CH: +480 (Peking)
TW: +480 (Taipei)
AS: +480 (Hong Kong)
KO: +540 (Korea)
[Auto Off Set]
Auto Off Limit Set
C
[0 or 1 / 0 / 1/step]
0: Service management
C
1: User management
[0 or 1 / 0 / 1/step]
C
0: Off
1: On
C
[-1440 to 1440 / -300 / 1min./step]
[0 or 1 / 1 / 1/step]
C
0:Off, 1:On

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents