Setting the main and sub remote controllers
1. Set one of the 2 connected remote controllers as the main remote controller.
2. On the other remote controller (sub-remote controller), switch the remote controller address connector on the
rear of the remote controller PCB from Main to Sub. When the connector has been switched, the remote con-
troller will function as the sub-remote controller.
The sub-remote controller will also operate when connected to the indoor unit (indoor unit 2 or 3).
NOTE
Cautions on group control
G
Group control within the same refrigerant tub-
ing system is recommended.
[Tubing system which is NOT recommended]
Tubing
system 2
3
<Example 1> In the MULTISET system, group control
extending over tubing systems becomes
impossible to set, which means the
indoor units cannot operate.
While Group 4 is in heating operation, if later Group 3
begins cooling operation, indoor units 1, 2 of Group 3
can be operated, but the indoor units 3-6 of Group 4
cannot operate.
2/8/06
4:32 PM
Page 79
To Service Technicians
To display the sensor temperature:
Press both
and
buttons on the
remote controller for more than 4 seconds
together.
Change the sensor address (CODE NO.)
with
/
(SET TEMP) buttons.
Select the UNIT NO. that you want to call
with
button.
Press the
button to finish service mode.
RCU.Main
RCU.CK
RCU.Sub
RCU
TMNL.
To avoid an electric shock hazard,
WA R N I N G
DO NOT touch any ter-
minal on the Printed Cir-
cuit Board with a metal rod, a
screwdriver edge or bare hand
when power
is supplied.
Outdoor units
Tubing system 1
2
1
3
2
1
3
2
1
Group 3
Group 2
Indoor Units
4
5
6
2
1
Group 4
TIMER
TMNL.
To display the trouble history:
Press both
and
buttons on the
remote controller for more than 4 seconds
together.
Change the alarm message:
/
(SET TEMP) buttons
CODE NO.
(New) (Old)
Press the
button to finish service
mode.
Changing method for room
temperature sensor (from Indoor
unit to RCU)
On the remote controller, press
1
+
+
at the same time for
more than 4 seconds.
RCU.ADR
Set CODE No.
with
/
2
(SET TEMP) button.
Set DATA from
to
3
with
/
(TIMER) button.
Press
4
Finally, Press
Fig. 6-6
Group address
Group 1
Remote
controller
79
Remote controller
address connector
Remote Controller (Main)
Remote Controller (Sub)