Example:AT+ WMCFG =4
Note: 1. After setting a new mode, it needs to be reset or power off and restart
AT+DINFO Get facility information
AT+DINFO=ALLNODE
5
AT+DINFO=SELFS
AT+DINFO=SELFE
Example:AT+DINFO=SELFE
AT+ TFOCFG Setting/Querying output format configuration (reboot valid)
AT+ TFOCFG=?
6
AT+ TFOCFG=Value
Example:AT+ TFCFG=0
AT+ TFICFG Setting/Querying input transmission format configuration (reboot valid)
7
AT+ TFICFG=?
AT+ TFICFG=Value
Chengdu Ebyte Electronic Technology Co,;Ltd
Copyright ©2012–2019,
2, Dormant Node;
3, Sleep mode;
4, (factory default), dial switch control
Description:
Query the short and long address of all node, and return by UART.
It works only when the device works in the coordinator mode
Description:
Get short address and return by UART
Description:
Get long address and return by UART
Description:
Gets output format configuration
Response:
TFOCFG:0
Description:
Value:0~7
0:Output: valid data (transparent transmission))
1: Output: Valid Data +Long Address
2:Output: Valid Data +Short Address
3:Output: Valid Data+RSSI
4:Output:Valid Data+Long Address+Short Address
5:Output:Valid Data+Long Address+RSSI
6:Output:Valid Data+Short Address+RSSI
7:Output:Valid Data+Long Address+Short Address+RSSI
Description:
Gets input transmission format configuration
Response:
TFICFG:0
Description:
E70-433NW30S user manual