Outdoor Unit Installation Instructions B. Outdoor Unit Types And Specifications C. Notes On Drilling Hole In Wall - intensity IDUFCI60KC-3 Installation Manual

Table of Contents

Advertisement

NOTE: The minimum distance between the
outdoor unit and walls described in the
installation guide does not apply to airtight
rooms. Be sure to keep the unit unobstructed
in at least two of the three directions (M, N, P)
(See Fig. 5.10)
M
N
Fig. 5.10
Rows of series installation
Table 5.3 The relations between H, A and L
are as follows.
L
L ≤ 1/2H
L ≤ H
1/2H < L ≤ H
Can not be installed
L > H
H
P
A
25 cm / 9.8" or more
30 cm / 11.8" or more
Fig. 5.11
Drain Joint Installation
Before bolting the outdoor unit in place, you
must install the drain joint at the bottom of the
unit. (See Fig. 5.12)
Fit the rubber seal on the end of the drain
1.
joint that will connect to the outdoor unit.
Insert the drain joint into the hole in the
2.
base pan of the unit.
Rotate the drain joint 90° until it clicks in
3.
place facing the front of the unit.
Connect a drain hose extension (not
4.
included) to the drain joint to redirect water
from the unit during heating mode.
NOTE: Make sure the water drains to a safe
location where it will not cause water damage
or a slipping hazard.
Seal
Drain joint
(A)
Notes On Drilling Hole In Wall
You must drill a hole in the wall for the
refrigerant piping, and the signal cable that will
connect the indoor and outdoor units.
L
Determine the location of the wall hole
1.
based on the location of the outdoor unit.
Using a 65-mm (2.5") core drill, drill a hole
2.
in the wall.
NOTE: When drilling the wall hole, make
sure to avoid wires, plumbing, and other
sensitive components.
Place the protective wall cuff in the hole.
3.
This protects the edges of the hole and will
help seal it when you finish the installation
process.
Base pan hole of
outdoor unit
Seal
(B)
Fig. 5.12
Page 15