5. INSTALLATION INSTRUCTIONS
This appliance is adjusted for NATURAL GAS at 20mbar ONLY.
The hob is suitable for conversion to Liquid Petroleum Gas BUTANE (G30) at 28-30 mbar and PROPANE
(G31) at 37 mbar by the following procedure using the kit supplied.
Replace the injectors with the corresponding injector from the table on page below.
First remove the burner caps and rings and with a socket spanner "B", unscrew injector "A" (see fig.7).
The adjustment of the reduced rate position is as follows (fig. 8):
Light the burner and turn the knob to reduced rate position.
Remove the knob "M" which is simply inserted onto tap stem.
Insert a small screwdriver "C" into the top shaft "F" and turn the bypass screw left or right until flame of
the burner is conveniently regulated to the low position.
Make sure that when turning quickly from "Full on" position
to reduced rate position that the burner does not extinguish.
FIG. 7
BURNERS
DESCRIPTION
1
ULTRA RAPID
2
RAPID
SEMIRAPID
3
FRONT RIGHT
SEMIRAPID
4
REAR LEFT
5
AUXILIARY
FIG. 8
BURNER TECHNICAL DATA TABLE
NORMAL
PRESSURE
GAS
mbar
BUTANE
28 - 30
PROPANE
37
NATURAL
20
BUTANE
28 - 30
PROPANE
37
NATURAL
20
BUTANE
28 - 30
PROPANE
37
NATURAL
20
BUTANE
28 - 30
PROPANE
37
NATURAL
20
BUTANE
28 - 30
PROPANE
37
NATURAL
20
NORMAL
INJECTOR
RATE
DIAMETER
g/h
l/h
1/100 mm
225
90
222
90
295
121 Y
204
83
200
83
267
117 S
102
58
100
58
133
85 Y
127
65
125
65
167
97 Z
73
50
71
50
95
72 X
9
NOMINAL HEAT
INPUT (W)
PASS
MIN.
MAX.
1/100 mm
1400
3100
1400
3100
1400
3100
750
2800
750
2800
750
2800
500
1400
500
1400
500
1400
500
1750
500
1750
500
1750
400
1000
400
1000
400
1000
BY
62
62
62
41
41
41
32
32
32
32
32
32
30
30
30