Cardin Elettronica SL Series Manual page 17

Automation for sliding gates with a dc powered motor
Hide thumbs Also See for SL Series:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 14
Terminal board connection
1
Common for the emergency buttons
2
EMRG 2 (NO contact) emergency manoeuvring button input 2
3
EMRG 1 (NO contact) emergency manoeuvring button input 1
4
Common for all inputs and outputs.
5
30 Vdc output, powering external loads
6
Common for all inputs and outputs.
7
30 Vdc controlled output, powering external loads
8
Common for all inputs and outputs.
9
LS 24 Vdc 3W output for an indicator light.
10 LP 24 Vdc output for warning lights.
25W intermittent activation (50%), 12,5W continuous activation
11 Common for all inputs and outputs.
12 FTCI (NC contact) Safety and control devices in input (photocells
invert the travel direction when an obstruction is detected). Open-
ing this contact will provoke a travel direction inversion during
closure due to the cutting in of the safety device.
13 CSP (NC contact) Safety buffer input). Opening this contact will
provoke a travel direction inversion of 10 cm, a pause of 3 min-
utes, after which the motor will continue moving in the original
direction after a 10 second preflashing period has elapsed.
14 TB (NC contact) Stop button input (The opening of this contact
interrupts the cycle until a new movement command is given).
15 Common for all inputs and outputs.
16 TD (NO contact) Dynamic button input
17 TAL (NO contact) Limited opening button input
18 TC (NO contact) Closing button input
19 TA (NO contact) Opening button input
20 Outer conductor for radio receiver antenna
21 Inner conductor for radio receiver antenna (if an external antenna
is fitted use a coaxial cable RG58 with an impedance of 50 ).
Note
(1)
: The total of the 2 external device outputs must not exceed
10 W.
P3
L6
ON
1 2 3 4 5 6 7 8 9
21
20
19
CN1
Secondary Faston connection 24Vac logic power supply
CN2
Secondary Faston connection motor circuit power supply
V2:0Vac, V3:20Vac, V4:30Vac
CN3
Battery Faston connection
CN4
Motor Faston connection
CSER
Serial connection (only for diagnostics)
D1
Six-segment LED display
DS1
Selection dip-switch
(1)
.
(1)
.
L5
L8
L10
L9
L7
L11
DS1
P1
P2
L3
18
17
16
15
14
13
ALL UNUSED NC CONTACTS MUST BE JUMPED.
If the FTCI input has been jumped the FTCI security device test must
test both the transmission and receiver parts of the security devices
test is active there will be a 1 second delay between the command
transmission and movement of the gate.
Switch on the power and make sure that the indicator LEDS are in the
following condition (note: If the display is off you can press the PROG
key to show the status of the safety devices.
- L1
Power on
- L2
Wrong battery connection
- L3
Transmitter code programming indicator
- L4
Battery charging
- L5
- L6
- L7
- L8
- L9
- L10
- L11
Note
(2)
immediately.
(3)
Note
Note
(4)
Check that the activation of the safety devices switches
the corresponding LEDS off.
If the green power on LED doesn't light up check the condition of the
fuses and the power cable connection at the transformer primary.
If one or more of the safety LEDS do not light up check the contacts
of the relative security devices and check that the unused safety device
contacts have been bridged.
D1
L1
{
CN4
9
12
11
10
8
7
F1
15A blade fuse
F2
4A blade fuse
F3
15A blade fuse
operation)
F4
4A blade fuse
tion)
Note
: These are automotive type blade fuses
(1)
17
OFF
TB
TA
TC
TD/CH1
on
on
L4
F4
CN3
10
L2
BT
F1
15
CN2
V4 V3
M
F2
4
6
5
4
3
2
1
(1)
(motor power protection)
(1)
(24V circuit protection)
(1)
(motor power protection during battery
(1)
(24V circuit protection during battery opera-
FTCI
CTRL 30 Vdc
ON
OFF
(2)
OFF
OFF
(3)
ON
(4)
(4)
FTCI ON
(4)
CSP
ON
OFF
OFF
TAL
OFF
OFF
F3
BT
V2
CN1
V0
V1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl1524

Table of Contents