Testing the viewfinder
1
Adjust the position of the viewfinder.
2
Check that the color bars are displayed in the viewfinder, and adjust
the BRIGHT, CONTRAST, and PEAKING controls to give the best
color bar display.
3
Check each of the following operations.
• The menu is displayed on the viewfinder screen.
• Turn the MENU knob and check that the menu page changes to
the next page.
• Push the MENU knob and check that settings of each item of the
selected page are displayed.
• Turn the MENU knob and check that the arrow (→) mark moves
within the page.
• Push the MENU knob and check that the arrow (→) mark placed
before the item changes to the circle (z) and the circle (z) placed
before the setting of the item changes to the question mark (?).
• Turn the MENU knob and check that the setting of the selected
item or ON/OFF changes.
4
Set the OUTPUT/DCC switch to CAM, and change the inner
FILTER (ND filter) selector position in the sequence of 1, 2, 3 and
4, and the outer FILTER (CC filter) selector position in the sequence
B, C, D, A and B.
Check that the FILTER indicator on the viewfinder screen displays
the correct numbers.