Features
Tri-Mode Environmental Sensing:
Flood/Moisture Sensor
o
Freeze – for Furnace Failure
o
Overheat – for Furnace runaway or Air Conditioning failure.
o
Cover tamper.
Strong, reliable RF signal.
8-10 year battery life on CR123A battery.
Low Battery indication.
8.3x3.5x2.7cm
Key Instructions
Battery "+" faces towards spring.
Flood
Alarm: when liquid rises 0.040 inches above sensor bottom.
Tamper: when cover is opened.
Supervisory: every hour.
Freeze
Alarm: when room temperature drops below 40F.
Tamper: when cover is opened.
Supervisory: every hour.
Overheat
Alarm: when room temperature rises above 100F.
Tamper: when cover is opened.
Supervisory: every hour.
Enrollment
Place panel in enrollment mode.
Tamper the device.
By default the Flood will enroll first – to add just the Freeze or just the
overheat, or use all three, go to resolutionproducts.com/helixsetup
2
Specifications
Flood sensing:
Titanium contacts
100K-Ohm nominal (DO NOT use an EOL resistor)
Transmitter handles 1 or 2 flood elements, no more.
0.04 inch floor spacing to eliminate floor
condensation falses.
Checks for moisture every 5 seconds: needs two
positive moisture checks to send Flood alarm.
(test mode: every second when cover is off)
7.2°C +/- 16.6°C
Freeze Alarm:
Restores when temp increases 4F from alarm
37.7°C +/- 16.6°C
Overheat Alarm Temp:
Restores when temp decreases 4F from alarm
Mounting hardware:
#6 or #8 screws
Dual Mode mounting:
Screwed to floor
Screwed to wall
Terminal wire capacity:
16 Gauge
Replacement Battery:
CR123A 1550 mAH
-17°C to 48°C
Temperature Range:
8.3x3.5x2.7cm
Housing dimensions:
Specifications subject to change without notice.
Internal & Close-up Pictures
Temp Element
Strain relief for
floor mounting

Advertisement

loading

Summary of Contents for Resolution CONNECT O2

  • Page 1 Specifications CONNECT Flood sensing: Titanium contacts 100K-Ohm nominal (DO NOT use an EOL resistor) Transmitter handles 1 or 2 flood elements, no more. 0.04 inch floor spacing to eliminate floor condensation falses. Checks for moisture every 5 seconds: needs two positive moisture checks to send Flood alarm.
  • Page 2 This device must accept any interference that may be received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the Resolution Products, Inc. could void the user's authority to operate this equipment. FCC ID: U5X-RE301 IC Notice This device complies with Industry Canada license-exempt RSS standard(s).

This manual is also suitable for:

Re619