RE219
Flood/Temp Range, Honeywell
Home Disaster™ Sensor
Features
Tri-Mode Environmental Sensing:
•
Flood/Moisture Sensor
o
Freeze – for Furnace Failure
o
Overheat – for Furnace runaway or Air Conditioning failure.
o
3 unique wireless Loops: one for each function
•
Cover tamper.
•
Strong, reliable RF signal.
•
8-10 year battery life on CR123A battery.
•
Low Battery indication.
•
3.3x1.4x1.1 inches.
•
Key Instructions
Battery "+" faces towards spring.
•
Enrolling:
•
To monitor multiple functions, repeat the below RF Enrollment process; each
time with the SAME serial number, but with a DIFFERENT Loop number.
Honeywell Vista and Lynx Settings
Place Panel in Zone Programming mode (e.g. *56).
•
Zone Type = for example, 24-Hr. Aux.
•
Input Type = Supervised RF Transmitter.
•
When asked for serial number, press Tamper switch.
•
Program the desired Loop number you want that zone to monitor. Loop
•
functions are:
Loop 1: Overheat.
Loop 2: Flood.
Loop 3: Freeze.
Loop 4: Tamper.
2GIG Go! Panel Settings – go to: Q1
2GIG® Settings for Flood:
2GIG® Settings for Freeze:
Zone Type – [08] 24 Hr Aux
Zone Type – [08] 24 Hr Aux
Equip Type – [8] water
Equip Type – [6] freeze
Equip Code – [0556] existing
Equip Code – [0556] existing
flood/temp sensor
flood/temp sensor
Enter RF Serial # - Press Shift +
Enter RF Serial # - Press Shift +
Learn, Trip Zone
Learn, Trip Zone
(verify ID with sensor label on
(verify ID with sensor label on
battery)
battery)
Equip Age – [0] New
Equip Age – [0] New
Loop – [2] (Flood)
Loop – [3] (Freeze)
Voice Desc: 087, 191
Voice Desc: 096, 191
"Flood Sensor"
RE219_Honeywell_Flood_Temp_Instructions Page 1 of 4
24-Hour Tech Support Line: (715)808-0164
www.ResolutionProducts.com
®
-Compatible
2GIG® Settings for Overheat:
Zone Type – [08] 24 Hr Aux
Equip Type – [10] temperature
Equip Code – [0708] existing
heat sensor
Enter RF Serial # - Press Shift +
Learn, Trip Zone
(verify ID with sensor label on
battery)
Equip Age – [0] New
Loop – [1] (Overheat)
Voice Desc: 112, 224, 191
"High Temperature Sensor"
"Freeze Sensor"
27-Jan-15
Test Temp alarm functions by putting in a freezer, or blowing a hair dryer on
•
sensor.
Test Flood alarm function by putting sensor in water
•
(distilled water will not work, but tap water should).
NOTE: Sensor reacts within 3 seconds when cover is off; 30 seconds when
cover on.
Operation
Flood – Loop 2:
•
Alarm: when liquid rises 0.040 inches above sensor bottom.
Tamper: when cover is opened.
Supervisory: every hour.
Freeze – Loop 3
•
Alarm: when room temperature drops below 40F.
Tamper: when cover is opened.
Supervisory: every hour.
Overheat – Loop 1
•
Alarm: when room temperature rises above 100F.
Tamper: when cover is opened.
Supervisory: every hour.
RE219_Honeywell_Flood_Temp_Instructions Page 2 of 4
24-Hour Tech Support Line: (715)808-0164
www.ResolutionProducts.com
27-Jan-15