Flood/temp range, honeywell-compatible home disaster sensor

Advertisement

Quick Links

RE219
Flood/Temp Range, Honeywell
Home Disaster™ Sensor
Features
Tri-Mode Environmental Sensing:
Flood/Moisture Sensor
o
Freeze – for Furnace Failure
o
Overheat – for Furnace runaway or Air Conditioning failure.
o
3 unique wireless Loops: one for each function
Cover tamper.
Strong, reliable RF signal.
8-10 year battery life on CR123A battery.
Low Battery indication.
3.3x1.4x1.1 inches.
Key Instructions
Battery "+" faces towards spring.
Enrolling:
To monitor multiple functions, repeat the below RF Enrollment process; each
time with the SAME serial number, but with a DIFFERENT Loop number.
Honeywell Vista and Lynx Settings
Place Panel in Zone Programming mode (e.g. *56).
Zone Type = for example, 24-Hr. Aux.
Input Type = Supervised RF Transmitter.
When asked for serial number, press Tamper switch.
Program the desired Loop number you want that zone to monitor. Loop
functions are:
Loop 1: Overheat.
Loop 2: Flood.
Loop 3: Freeze.
Loop 4: Tamper.
2GIG Go! Panel Settings – go to: Q1
2GIG® Settings for Flood:
2GIG® Settings for Freeze:
Zone Type – [08] 24 Hr Aux
Zone Type – [08] 24 Hr Aux
Equip Type – [8] water
Equip Type – [6] freeze
Equip Code – [0556] existing
Equip Code – [0556] existing
flood/temp sensor
flood/temp sensor
Enter RF Serial # - Press Shift +
Enter RF Serial # - Press Shift +
Learn, Trip Zone
Learn, Trip Zone
(verify ID with sensor label on
(verify ID with sensor label on
battery)
battery)
Equip Age – [0] New
Equip Age – [0] New
Loop – [2] (Flood)
Loop – [3] (Freeze)
Voice Desc: 087, 191
Voice Desc: 096, 191
"Flood Sensor"
RE219_Honeywell_Flood_Temp_Instructions Page 1 of 4
24-Hour Tech Support Line: (715)808-0164
www.ResolutionProducts.com
®
-Compatible
2GIG® Settings for Overheat:
Zone Type – [08] 24 Hr Aux
Equip Type – [10] temperature
Equip Code – [0708] existing
heat sensor
Enter RF Serial # - Press Shift +
Learn, Trip Zone
(verify ID with sensor label on
battery)
Equip Age – [0] New
Loop – [1] (Overheat)
Voice Desc: 112, 224, 191
"High Temperature Sensor"
"Freeze Sensor"
27-Jan-15
Test Temp alarm functions by putting in a freezer, or blowing a hair dryer on
sensor.
Test Flood alarm function by putting sensor in water
(distilled water will not work, but tap water should).
NOTE: Sensor reacts within 3 seconds when cover is off; 30 seconds when
cover on.
Operation
Flood – Loop 2:
Alarm: when liquid rises 0.040 inches above sensor bottom.
Tamper: when cover is opened.
Supervisory: every hour.
Freeze – Loop 3
Alarm: when room temperature drops below 40F.
Tamper: when cover is opened.
Supervisory: every hour.
Overheat – Loop 1
Alarm: when room temperature rises above 100F.
Tamper: when cover is opened.
Supervisory: every hour.
RE219_Honeywell_Flood_Temp_Instructions Page 2 of 4
24-Hour Tech Support Line: (715)808-0164
www.ResolutionProducts.com
27-Jan-15

Advertisement

loading
Need help?

Need help?

Do you have a question about the RE219 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Resolution RE219

  • Page 1 Test Temp alarm functions by putting in a freezer, or blowing a hair dryer on • sensor. Test Flood alarm function by putting sensor in water • RE219 Flood/Temp Range, Honeywell ® -Compatible (distilled water will not work, but tap water should).
  • Page 2 100K-Ohm nominal (DO NOT use an EOL resistor) Transmitter handles 1 or 2 flood elements, no more. Resolution Products, Inc. products will function with one of either GE, DSC or Honeywell systems. 0.04 inch floor spacing to eliminate floor However, no Resolution product is produced by, endorsed by, nor is officially associated with GE, condensation falses.