ENGLISH
Quick Installation Guide
MRO-L
These short operating instructions apply for the following devices of INSYS icom:
▪ MRO-L200
▪ MRO-L210
It is intended for a quick commissioning by the operator. Refer to the associated manual for further information.
This and other associated manuals can be found on our website in the menu Support and Downloads >
Documentation. Scan the QR code above or enter the URL into your web browser.
Tec hnical Data
The product is only intended for the use within the permissible technical limits specified in the data sheets. These limits must be observed.
Operating voltage
Power consumption
Level input IN1
Current consumption input
IN1 at LOW potential
Level input IN2
Power consumption input
IN2 at HIGH potential
Digital output (open
collector), max. load
Max. voltage drop of output
in state ON
Tec hnical Boundaries
Max. line length for antennas, power supplies, serial interfaces, inputs and outputs as well as other signals: 30 m
Cable cross-section: 0.25 ... 1.5 (2.5) mm² (depending on terminal size), flexible lines require end sleeves
Su pport
If you need further support, please contact your sales partner or INSYS icom support. You can contact our support department via e-mail
under support@insys-tec.de.
Defects liability terms
A use other than the intended use, an ignorance of the safety instructions and the documentation, the use of insufficiently qualified
personnel as well as unauthorised modifications exclude the liability of the manufacturer for damages resulting from this. The liabilit y of the
manufacturer ceases to exist.
Int ended Use
The product may only be used for the purposes specified in the function overview of the manual. In addition, it may be used for the
following purposes:
▪ Usage and mounting in an industrial cabinet.
▪ Switching and data transmission functions in machines according to the machine directive 2006/42/EC.
▪ Usage as data transmission device, e.g. for a PLC.
The product may not be used for the following purposes and used or operated under the following conditions:
▪ Use, control, switching and data transmission in machines or systems in explosive atmospheres.
▪ Controlling, switching and data transmission of machines, which may involve risks to life and limb due to their functions or when a
breakdown occurs.
12 V ... 24 V DC (±20%)
typ. 2.5 W, max. 8 W
HIGH level = 2 ... 24 V
LOW level = 0 ... 1 V
Contact open condition: HIGH
typ. 0.1 mA when connecting
to GND
HIGH level = 10 ... 24 V
LOW level = 0 ... 5 V
Contact open condition: LOW
max. 3 mA at 24 V DC
24 V (DC), 100 mA
< 1 V (DC) at 100 mA load
www.insys-icom.com/manual
LTE frequencies (4G)
800, 900, 1800, 2100, 2600 MHz (L-200)
700, 850, 1700/2100 (AWS), 1900 MHz
(L-210)
UMTS/HSPA
900, 1800, 2100 MHz (L-200)
frequencies (3G)
850, 1700/2100 (AWS), 1900 MHz (L-210)
GSM/GPRS frequencies
900, 1800 MHz (L-200)
(2G)
850, 900, 1800, 1900 MHz (L-210)
Real-time clock (RTC)
typ. 2 days
buffer time
-30 °C ... 70 °C
Temperature range
(75 °C extended)
Maximum permissible
95% non-condensing
humidity
IP rating
Housing IP40
www.insys-icom.com