Download Print this page
insys icom ECR-LW300 Quick Installation Manual

insys icom ECR-LW300 Quick Installation Manual

Advertisement

Quick Links

ENGLISH
Quick Installation Guide
ECR-LW
These short operating instructions apply for the following devices of INSYS icom:
▪ ECR-LW300
▪ ECR-LW320
It is intended for a quick commissioning by the operator. Refer to the associated manual for further information.
This and other associated manuals can be found on our website in the menu Support and Downloads >
Documentation. Scan the QR code above or enter the URL into your web browser.
Tec hnical Data
The product is only intended for the use within the permissible technical limits specified in the data sheets. These limits must be observed.
Operating voltage
Power consumption
Level input
Current consumption input at
HIGH potential
Digital output (open
collector), max. load
Max. voltage drop of the
output in condition ON
Output power WLAN (Wi-Fi)
Tec hnical Boundaries
Max. line lengths for antennas, power supply, serial interfaces, inputs and outputs as well as other signals: 30 m
Cable cross-section: 0.25 ... 1.5 mm², flexible lines require end sleeves
Su pport
If you need further support, please contact your sales partner or INSYS icom support. You can contact our support department via e-mail
under support@insys-tec.de.
Defects Liability Terms
A use other than the intended use, an ignorance of the safety instructions and the documentation, the use of insufficiently qualified
personnel as well as unauthorised modifications exclude the liability of the manufacturer for damages resulting from this. The liability of the
manufacturer ceases to exist.
Int ended Use
The product may only be used for the purposes specified in the function overview of the manual. In addition, it may be used for the
following purposes:
▪ Usage and mounting in an industrial cabinet.
▪ Switching and data transmission functions in machines according to the machine directive 2006/42/EC.
▪ Usage as data transmission device, e.g. for a PLC.
The product may not be used for the following purposes and used or operated under the following conditions:
▪ Use, control, switching and data transmission in machines or systems in explosive atmospheres.
▪ Controlling, switching and data transmission of machines, which may involve risks to life and limb due to their functions or when a
breakdown occurs.
12 V ... 24 V DC (±20%)
typ. 3 W, max. 7 W
HIGH level = 10 ... 24 V
LOW level = 0 ... 5 V
Contact open condition: LOW
max. 3 mA at 24 V DC
24 V (DC), 100 mA
< 1 V (DC) at 100 mA load
max. 100 mW
www.insys-icom.com/manual 
LTE frequencies (4G)
UMTS/HSPA frequencies
(3G)
GSM/GPRS frequencies
(2G)
Temperature range
Maximum permissible
humidity
IP rating
700, 800, 900, 1800, 2100 MHz
bands 1, 3, 8, 20, 28 (ECR-LW300)
700, 850, 900, 1800 MHz
bands 3, 5, 8, 28 (ECR-LW320)
900, 2100 MHz, bd. 1, 8 (ECR-LW300)
850, 900, 2100 MHz
bands 1, 5, 8 (ECR-LW320)
900, 1800 MHz (ECR-LW300)
-30 °C ... 70 °C
(75 °C extended)
95% non-condensing
Housing IP40
www.insys-icom.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the ECR-LW300 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for insys icom ECR-LW300

  • Page 1 Cable cross-section: 0.25 … 1.5 mm², flexible lines require end sleeves Su pport If you need further support, please contact your sales partner or INSYS icom support. You can contact our support department via e-mail under support@insys-tec.de. Defects Liability Terms A use other than the intended use, an ignorance of the safety instructions and the documentation, the use of insufficiently qualified personnel as well as unauthorised modifications exclude the liability of the manufacturer for damages resulting from this.
  • Page 2 ENGLISH Quick Installation Guide ECR-LW Router connection Insert SIM card (Mini-SIM, 2FF) with contacts facing to the front and chamfer facing to the router into “SIM 1” slot Connect antenna to connection LTE (SMA (f)). The screen of the antenna system must be connected to the protective conductor when using an outside mounted antenna! Connect supply voltage (12 V …...
  • Page 3 ENGLISH Quick Installation Guide ECR-LW Configuration as Internet router via cellular radio In Menu Help > Wizards: Select Startup Wizard Select Internet access via Cellular network (refer to inline help for WAN over Ethernet)  The following data can be found in the contract documents of your SIM card or can be requested from the provider.
  • Page 4 ENGLISH Quick Installation Guide ECR-LW Availability of the router upon configuration  The wizard deactivates the configuration network (IP net 1) and assigns ETH1 to the local application network (IP net 2). In addition, it configures the previous default address 192.168.1.1 as additional IP address for IP net 2 that the configuration PC still has access after executing the wizard (if this has not already been assigned in the local application network).

This manual is also suitable for:

Ecr-lw320Ecr-lw