Daikin Altherma 3 R F Installer's Reference Manual page 241

Hide thumbs Also See for Altherma 3 R F:
Table of Contents

Advertisement

ERGA04~08E + EHVZ04+08S18+23E
Daikin Altherma 3 R F
4P629093-1B – 2022.05
Error code
H1-00
External temperature sensor problem
H3-00
OU: Malfunction of high pressure switch (HPS)
H5-00
Malfunction of compressor overload protection
H6-00
OU: Malfunction of position detection sensor
H8-00
OU: Malfunction of compressor input (CT)
system
H9-00
OU: Malfunction of outdoor air thermistor
HC-00
Tank temperature sensor problem
HC-01
Second tank temperature sensor problem
HJ-10
Water pressure sensor abnormality
J3-00
OU: Malfunction of discharge pipe thermistor
J6-00
OU: Malfunction of heat exchanger thermistor
J6-07
OU: Malfunction of heat exchanger thermistor
JA-00
OU: Malfunction of high pressure sensor
L1-00
Malfunction of INV PCB
L3-00
OU: Electrical box temperature rise problem
L4-00
OU: Malfunction of inverter radiating fin
temperature rise
L5-00
OU: Inverter instantaneous overcurrent (DC)
L8-00
Malfunction triggered by a thermal protection
in the inverter PCB
L9-00
Prevention of compressor lock
LC-00
Malfunction in communication system of outdoor
unit
P1-00
Open-phase power supply imbalance
P3-00
Abnormal direct current
P4-00
OU: Malfunction of radiating fin temperature
sensor
PJ-00
Capacity setting mismatch
U0-00
OU: Shortage of refrigerant
U1-00
Malfunction by reverse phase/open-phase
U2-00
OU: Defect of power supply voltage
U3-00
Underfloor heating screed dryout function not
completed correctly
U4-00
Indoor/outdoor unit communication problem
U5-00
User interface communication problem
14
Troubleshooting
|
Description
Installer reference guide
241

Advertisement

Table of Contents
loading

Table of Contents