Daikin Altherma 3 R F Installer's Reference Manual page 172

Hide thumbs Also See for Altherma 3 R F:
Table of Contents

Advertisement

10
|
Configuration
Installer reference guide
172
[9-0D]/[9-0E]=4/8
a (kPa)
a External static pressure
b Water flow rate
Pump outside range
When the pump operation function is disabled the pump will stop if the outdoor
temperature is higher than the value set by the Space
temperature [4‑02]. When the pump operation is enabled, the pump operation
is possible at all outdoor temperatures.
#
Code
[4.9]
[F-00]
Increase around 0°C
Use this setting to compensate for possible heat losses of the building due to the
evaporation of melted ice or snow. (e.g. in cold region countries).
In heating operation, the desired leaving water temperature is locally increased
around an outdoor temperature of 0°C.This compensation can be selected when
using an absolute or a weather dependent desired temperature (see illustration
below).
T
T
t
t
L
R
T
A
0°C
a
a Absolute desired LWT
b Weather dependent desired LWT
#
Code
[4.A]
[D-03]
Overshoot
Restriction: This function is only applicable in heating mode.
b (l/min)
Pump operation:
0: Disabled if outdoor temperature is higher
than [4‑02].
1: Possible at all outdoor temperatures.
L
R
T
A
0°C
b
Increase around 0°C:
0: No
1: increase 2°C, span 4°C
2: increase 4°C, span 4°C
3: increase 2°C, span 8°C
4: increase 4°C, span 8°C
heating
Description
Description
ERGA04~08E + EHVZ04+08S18+23E
Daikin Altherma 3 R F
4P629093-1B – 2022.05
off

Advertisement

Table of Contents
loading

Table of Contents