Mounting location of Shower Arm Strap is variable but required.
structure is capable of supporting the product in use.
Mark location of mounting holes for Shower Arm Strap (1) referencing the rough-in diagram contained in this document.
Install
Shower Arm Strap
(1) to upper pipe using Supplied Screws. In drywall or tile applications, be sure to use appropriate
hardware.
If you are performing a
If you are performing a
Back-to-Back
Standard Installation,
Installation, please
please skip to
continue to STEPS 7 & 8.
STEP 9.
7
BACK-TO-BACK INSTALLATION
Your Shower Valve has the ability to be mounted back-to-back with another Valve in a shared space. This means the HOT and COLD
inlets may be reversed. Please see the following steps to adapt your valve for back-to-back mounting or reversed inlet supplies.
If the HOT and COLD water supplies are reversed (HOT on right and COLD on left), disassemble Valve Cartridge as outlined in STEP 8.
Please proceed to
STEP 8.
Installation
H
Normal Installation
(shown without Bonnet)
NOTE: Never install the valve body upside down!
9
TEMPERATURE LIMIT ADJUSTMENT
The maximum outlet temperature setting adjustment
(Temperature Limit Stop (TLS)) of the Valve has been factory set
at 1 10° F. To adjust the limit of the maximum outlet temperature
the Valve delivers, adjust the Valve's temperature limit stop (TLS)
Plate.
• Slip the Retaining Clip away from the Spindle and the TLS
Plate towards the end of the Spindle.
• With the water supplies "On", rotate the Valve Spindle
clockwise to the maximum desired outlet temperature.
• Position the TLS Plate so it contacts the Lug on the Bonnet
and therefore restricts the clockwise rotation of the Spindle.
• Slip the Retaining Clip back into the groove of the Spindle to
hold the TLS plate in place.
• Rotate the Spindle counter-clockwise to the "Off" position.
NOTE: A thermometer can be held at the Valve outlet to aid in either checking the existing factory setting
or reaching the desired outlet temperature.
Verify that the mounting location and
Normal Installation
(changes not required)
Reverse
C
Reverse Installation
(shown without Bonnet)
TLS PLATE
8
VALVE CARTRIDGE ADJUSTMENT/RE-INSTALLATION
• Gently remove the Retaining Clip ❶ and TLS Plate ❷ and keep them aside for later use.
Ensure that the water supplies are turned "OFF". Adjust the Cartridge Assembly by following the steps below.
• Using a Phillips Head Screwdriver, remove the four (x4) Bonnet Screws ❸.
• Using a Flat Tip Screwdriver, separate the Bonnet ❹ from the Cartridge Housing ❻ by gently prying
• Pull out the Cartridge assembly from the Valve Body.
between the Flange of the Bonnet ❹ and Cartridge Housing ❻ to release the engagement. • Pull out the
Cartridge ❺ from the Housing ❻.
• Rotate the Cartridge ❺ 180º so the "H" is now present at the 3 o'clock position.
• Insert the Cartridge ❺ into the Cartridge Housing ❻.
• Position the Bonnet ❹ over the Cartridge ❺ and snap the Bonnet ❹ into the Cartridge Housing ❻ while
• Reinstall the Cartridge Assembly into the Valve Body while ensuring the Large O-Ring ❼ is properly seated.
aligning the tabs and slots accordingly.
• Secure the Cartridge Assembly with the four (x4) Bonnet Screws ❸.
• See STEP 9 for TLS Adjustment and re-installation of the TLS Plate ❷ and Retaining Clip ❶.
10
Slide on the Dial Cap (1) onto the Bonnet. Tighten in place with the Dial Cap Screw (2). Slide the Handle (3) onto the Valve
post. Then secure into position with Handle Screw (4).
BONNET LUG
CLIP
3/32"
HANDLE AND DIAL CAP INSTALLATION
ROTAT
E