Table 4-1 Communication Interface Programming Setting Command Summary - Prodigit 4016 Series Operation Manual

Table of Contents

Advertisement

48 PRODIGIT

Table 4-1 Communication Interface programming setting command summary

COMMAND
OUT {SP}{0 | 1 | ON | OFF} {; | NL}
MODE{SP}{0 | 1 | AC | DC}{; | NL}
METER{SP}{0~7}{; | NL}
VRANG{SP}{0~6}{; | NL}
IRANG{SP}{0~18}{; | NL}
SHUNT{SP}{0 | 1 | INT | EXT}{; | NL}
FILTER{SP}{0 | 1}{; | NL}
ONDEG{SP}{0 ~ 359}{; | NL}
OFFDEG{SP}{0 ~ 359}{; | NL}
GRAPHT{SP}{0~100.00}{; | NL}
REMote{; | NL}
LOCAL{; | NL}
CLEAR{; | NL}
ONTIME{SP}{0.200~600.000}{; | NL}
OFFTIME{SP}{0.200~600.000}{; | NL}
REPEAT{SP}{1~9999}{; | NL}
SCALE {1~10000} {; | NL}
LOCK (0 | 1) {; | NL}
AUTOUP{SP}{0 | 1 | ON | OFF}{; | NL}
THD{SP}{0 || 1} { ; | NL}
GRAPH {SP} { ; | NL}
備註
Set Output
Set AC/DC Mode
Set Meter Mode
Set VRange
Set IRange
Set Shunt INT/EXT
Set FILTER
Set On Degree
Set Off Degree
Set_Inrush Graph T
Set Remote
Set Local
Clear MaxMin Data
Set Output OnTime
Set Ourput OffTime
Set Outpit Repeat
Set ext input scale
Set data lock
Set Range Auto Up
Set THD Mode
Set Inrush Graph Mode

Advertisement

Table of Contents
loading

Table of Contents