Maintenance

Instructions
1) Always turn off the valve before cleaning. For
relighting, refer to lighting instructions. Keep
the burner and control compartment clean by
brushing and vacuuming at least once a year.
When cleaning the logs, use a soft clean paint
brush as the logs are fragile and easily damaged.
2) Clean glass (never when unit is hot), appliance,
and door with a damp cloth. Never use an
abrasive cleaner.
3) The heater is finished in a porcelain finish or
with a heat resistant paint and should only be
refinished with heat resistant paint (not with
wall paint).
Never use an abrasive cleaner on the porcelain
finish as it may scratch the surface.
4) Make a periodic check of burner for proper po-
sition and condition. Visually check the flame of
the burner periodically, making sure the flames
are steady; not lifting or floating. If there is a
problem, call a qualified service person.
5) CAUTION: Label all wires prior to disconnection
when servicing controls. Wiring errors can cause
improper and dangerous operation.
6) The appliance and venting system must be
inspected before use, and at least annually,
by a qualified field service person, to ensure
that the flow of combustion and ventilation air
is not obstructed.
During the annual service call, the burners
should be removed from the burner tray and
cleaned. Replace the embers but do not block
the pilot.
7) Keep the area near the appliance clear and free
from combustible materials, gasoline, and other
flammable vapours and liquids.
W A R N I N G : C H I L D R E N A N D
ADULTS SHOULD BE ALERTED TO
THE HAZARDS OF HIGH SURFACE
TEMPERATURE AND SHOULD
STAY AWAY TO AVOID BURNS OR
CLOTHING IGNITION.
CHILDREN SHOULD BE CARE-
FULLY SUPERVISED WHEN THEY
ARE IN THE SAME ROOM AS THE
APPLIANCE.
DO NOT USE THIS APPLIANCE IF
ANY PART HAS BEEN UNDER WA-
TER. IMMEDIATELY CALL A QUAL-
IFIED SERVICE TECHNICIAN TO
INSPECT THE APPLIANCE AND TO
REPLACE ANY PART OF CONTROL
SYSTEM AND ANY GAS CONTROL
WHICH HAS BEEN UNDER WATER.
CLOTHING OR OTHER FLAMMA-
BLE MATERIAL SHOULD NOT BE
PLACED ON OR NEAR THE APPLI-
ANCE.
CAUTION: ANY SAFETY SCREEN
OR GUARD REMOVED FOR SER-
VICING AN APPLIANCE MUST BE
REPLACED PRIOR TO OPERATING
THE APPLIANCE.
8) Each time the appliance is lit, it may cause con-
densation and fog the glass. This condensation
and fog is normal and will disappear in a few
minutes as the glass heats up.
Never operate the appliance without the
glass properly secured in place.

Flame Pattern

Periodically check the pilot and main burner
flames. Correct pilot flame pattern has two
strong blue flames: 1 flowing around the
flame sensor and 1 flowing across the burner
(it does not have to be touching the burner).
YOUNG
N
ote: If you have an incorrect flame pattern,
contact your Regency
further instructions.
Incorrect flame pattern will have small,
probably yellow flames, not coming into
proper contact with the rear burner or flame
sensor.