Settings; Recommended Tap/Valve Settings; Cleaning, Care And Maintenance; Troubleshooting - STIEBEL ELTRON DHF13 C Operating & Installation

Hydraulically controlled instantaneous
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 18
OPERATION

Settings

4.
Settings
1
1 Partial load:
This setting is suitable for hand washing at a basin, for ex-
ample. At low flow rates, the appliance starts heating at half
the selected output.
2 Full load:
This setting is suitable for baths, showers and washing up,
for example. At low flow rates, the appliance starts heating
at half the selected output and at higher flow rates, the full
selected output.
f Click the output selector into the required position.
f
For start volumes, see chapter "Specification / Data table / On".
Recommended settings when using a thermostatic valve
f Set the output selector to full power.
f
4.1

Recommended tap/valve settings

Note
If the outlet temperature is not high enough when the
draw-off valve is fully open at full power, then more water
is flowing through the appliance than can be heated by
the heating system (appliance is at its output limit).
f Reduce the water volume at the draw-off valve.
f
Low draw-off rate = high outlet temperature
High draw-off rate = low outlet temperature
Twin lever tap
Output stage
Application range
Partial load
Washbasin
Full load
Bath, shower, sink
f If the temperature is too high, mix in some cold water.
f
Mono lever mixer
Output stage
Application range
Full load
All
f Turn the tap lever to the highest temperature.
f
f Fully open the tap.
f
f Increase the outlet temperature by closing the tap slowly.
f
f Reduce the outlet temperature by adding cold water or open-
f
ing the tap further, if possible.
www.stiebel-eltron.com
Following an interruption of the water supply
!
2
5.

Cleaning, care and maintenance

f Never use abrasive or corrosive cleaning agents. A damp
f
cloth is sufficient for cleaning the appliance.
f Check the taps regularly. Limescale deposits at the spouts
f
can be removed using commercially available descaling
agents.
6.

Troubleshooting

Problem
The appliance will not
start despite the DHW
valve being fully open.
If you cannot remedy the fault, notify your qualified contractor.
To facilitate and speed up your enquiry, please provide the serial
number from the type plate (000000-0000-00000):
Material losses
Following an interruption of the water supply, the
appliance must be recommissioned by carrying out the
following steps:
f Disconnect the appliance from the power supply by
f
removing the fuses/tripping the MCBs.
f Open the tap for one minute until the appliance and
f
its upstream cold water inlet line are free of air.
f Switch the mains power back ON again.
f
Cause
There is no power.
The flow rate is too low
for the appliance to start
heating at the selected
output. The aerator in
the tap or the shower
head is scaled up or con-
taminated.
Nr.: 000000-0000-00000
Remedy
Check the fuses/MCBs in
your fuse box/distribu-
tion panel.
Clean and/or descale the
aerator or shower head.
DHF-C |
21

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Dhf 15 cDhf18 cDhf 21 cDhf 24 cDhf 12 c1Dhf 13 c3

Table of Contents