Update Rate
Low Battery Indication
5.2 Electrical specyfication
Continuity test
NCV
2. VOLTAGE DC/AC
Function
Range
DC
VOLTAGE
(V)
(1000V)
AC
VOLTAGE
(V)
(750V)
* * Frequency response at AC modes: 40Hz ~ 1kHz.
* * Note: To prevent burning, do not measure voltage over 600V!
3. Resistance
Function
Range
600.0Ω
6.000kΩ
60.00kΩ
Resistance
600.0kΩ
6.000MΩ
60.00MΩ
4. AC/DC CURRENT
Function
Range
DCA
ACA
5. CAPACITANCE
Function
Range
Adres producenta/ Adresse des Herstellers/ Manufacturer's Address/ Адрес производителя
GTV Poland Sp. z o.o. Sp. k., ul. Przejazdowa 21, 05-800 Pruszków
√
√
Resolution
6V
0.001V
60V
0.01V
600V
0.1V
1V
6V
0.001V
60V
0.01V
600V
0.1V
1V
Resolution
0.1Ω
1Ω
10Ω
100Ω
1kΩ
10kΩ
Resolution
1A
1mA
10A
10mA
1A
1mA
10A
10mA
Resolution
3/s
Flashlight
√
Auto Power Off
Accuracy
Max
±(0.5%+5d)
600V
±(0.8%+5d)
±(1%+5d)
600V
±(1%+8d)
Accuracy
Max
±(1.3%+5d)
60MΩ
±(1.0%+5d)
±(1.5%+5d)
Accuracy
Max
±(1.0%+5d)
10A
±(1.2%+6d)
Accuracy
Max
√
√
9