HOGERT HT1E605 User Manual page 8

Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 6
4.1. Measure DC/AC Voltage (> 1V)
- Only when the voltage is higher than 1V, this product will show the display.
- Put the red lead into the terminal, put the black lead to the COM terminal.
- The DC or AC voltage will be auto matched.
- Touch the probes to the correct test points of the circuit to measure the voltage.
- Read the measured voltage on the display.
4.2. Measure Resistance
- Put the red lead into the
- The resistance measure will be auto matched.
- Touch the probes to the desired test points of the circuit to measure the resistance.
- Read the measured resistance on the display.
4.3. Test for Continuity
- Put the red lead into the
- The resistance measure will be auto matched.
- Touch the probes to the desired test points of
the circuit.
- The built-in beeper will beep when the resistance is lower than 50Ω, which indicates a short circuit while the central LED light will
light.
4.4. Test for NCV
- Push „SELECT„ one times to enter the „NCV„ Mode
- Pick up the tester and move it around, the built-in beeper will beep when the inner sensor detects AC voltage nearby. The stronger
the voltage is the quicker the beeper beeps while the central LED light will twinkle.
4.5. Test for capacitance
- Connect the black test lead to the COM terminal and the red lead to the Terminal.
- Push „SELECT" two times to enter the Capacitance Mode
- Connect the red probe to the anode side and the black probe to the cathode side of the capacitor being tested.
- Read the measured capacitance value on the display once the reading is stabilized.
4.6. Test for Frequency
- Connect the black test lead to the COM terminal and the red lead to the
- Push „SELECT" three times to enter the Frequency Mode
- Connect the test lead to the point to be measured of the circuit being tested.
- Read the measured Frequency value on the display once the reading is stabilized.
4.7. Test for Current
- Connect the black test lead to the „COM" and the red lead to the „10A„ Terminal.
- Push „SELECT" three times to enter the current Mode(A).
- Touch the probes to the correct test points of the circuit to measure the current.
- Read the measured current on the display
- When you input the current over 2 A the testing time should be less than 3 seconds
5. Electrical Specifications
5.1. Technical specification
Operating
Storage
Display
Ranging
Material
8
terminal, put the black lead to the COM terminal.
terminal, put the black lead to the COM terminal.
Environmental Specifications
Temperature
Humidity
Temperature
Humidity
General Specifications
6000 counts
Auto
ABS
Adres producenta/ Adresse des Herstellers/ Manufacturer's Address/ Адрес производителя
Terminal.
0~40°C
< 75%
-20~60°C
< 80%
Ture RMS
Data Hold
Backlight
GTV Poland Sp. z o.o. Sp. k., ul. Przejazdowa 21, 05-800 Pruszków