5.6
Positioning the probe - electrode
Before securing the burner to the boiler, check
(through the opening of the blast tube) that the
probe and electrode are correctly positioned, as in
Fig. 14.
WARNING
If in the previous check the position of the probe or electrode was
not correct, remove the screws 7)(Fig. 13 on page 18) extract the
inner part of the head 4)(Fig. 6 on page 12), and adjust them.
Installation
PROBE
ELECTRODE
2 - 4 mm
D11251
19
Do not rotate the probe but leave it as in Fig. 14; if
it is too close to the ignition electrode, it could
damage the control box amplifier.
WARNING
Respect the dimensions shown in Fig. 14.
WARNING
GB
Fig. 14
20148758