2-4. Check of SY-337 Board
2-4-1. Preparation
1. Start the check software for an SY board.
The start window of the check software for an SY
board is displayed.
SY board check application
SY board check application Ver 1.11
Connect
Camera connection
Common item
Sensor 1 check
Check
Sensor 2 check
Check
Serial terminal check
Check
Alarm out check
Check
LED check
Check
AUDIO (IN/OUT) check
Check
PC card check
Check
Security chip check
Check
2. Enter IP address "192.168.0.100" and click the
[Connect] button.
SY board check application
SY board check application Ver 1.11
Camera connection
Connect
Common item
Sensor 1 check
Check
Sensor 2 check
Check
Serial terminal check
Check
Alarm out check
Check
LED check
Check
AUDIO (IN/OUT) check
Check
PC card check
Check
Security chip check
Check
3. Confirm that "SNC-CS50N (P)" is displayed.
4. Perform steps (1) to (9) in "2-1-2. 4 Setting of camera".
n
"Failed to Connect" is displayed when an IP address is
not correctly set or when a camera does not operate
normally. In this case, set the IP address again.
2-4-2. Sensor 1 Check
1. Click the [Check] button for sensor 1 check.
2. Confirm that "OFF" is displayed on the window.
3. Click the [Check] button for sensor 1 check while
pressing and holding sensor input button 1 on the
alarm and serial IF tool board (referred to as an IF tool
board hereinafter).
4. Confirm that "ON" is displayed on the window.
SNC-CS50N/CS50P
Check
Check
Check
Check
Check
Check
Auto D/N check
Check
Manual D/N check
Check
ATW check
Check
One push WB check
Check
ATW-PRO check
Check
2-4-3. Sensor 2 Check
1. Change the connection on the IF tool board side from
pin 1 to pin 3 during connection between the IF tool
board and IF-954 board. (Refer to Section 2-1-3.)
2. Click the [Check] button for sensor 2 check.
3. Confirm that "OFF" is displayed on the window.
4. Click the [Check] button for sensor 2 check while
pressing and holding sensor input button 2 on the
board.
5. Confirm that "ON" is displayed on the window.
2-4-4. Serial Terminal Check
1. Click the [Check] button for serial terminal check.
2. Confirm that "OK" is displayed on the window.
2-4-5. Alarm Output Check
1. Click the [Check] button for alarm output check.
2. Confirm that LED1 and LED2 on the IF tool board
blink alternately.
LED for alarm 2
2-4-6. LED Check
1. Click the [Check] button for LED check.
2. Confirm that the LEDs of this unit operate as
described below.
Power LED:
Green → Goes off → Green → Goes off → Green ......
Network LED:
Green → Goes off → Orange → Goes off → Green →
Goes off → Yellow → Goes off → Green
LED for alarm 1
2-11 (E)