2-2-7. Read of Detection Data at 3200 K

1. Press the [Tab] key and display the message box
below.
n
This message box is displayed when you press the
[Tab] key with adjustment item BY Hue activated.
When this message box is incorrectly displayed, click
the [OK] button and then click the [No] button in the
next message box (refer to step 3). After that, press
the [Tab] key and activate the required adjustment
item.
2. Set steps (1) and (2) below with the message box
displayed.
(1) Shoot a 100% white pattern using this unit.
(2) Set the lens iris so that waveform level G satisfies
the specifications.
Object:
Measuring equipment: Waveform monitor
Specifications:
Waveform monitor
3. Click the [OK] button of the message box and read
detection data.
The numeric values of each edit box on the "WB Data
Take-in" panel change when read operation is
completed. The message box below is then displayed.
Yes
2-8 (E)
100% white pattern
G = 65 ±3 IRE (NTSC)
G = 460 ±21 mV (PAL)
G
No
4. Click the [Yes] button and save the read detection
data in EEPROM.
5. Click the [OK] button when the message box below is
displayed.
6. Perform "2-2-8. Termination processing".

2-2-8. Termination Processing

1. The message box below is displayed when step 5 in
Section 2-2-7 is performed.
Yes
2. Click the [Yes] button.
The message box below is displayed.
n
The current display returns to "3-2-6. Color
reproduction adjustment" when you click the [No]
button.
No