2-2. Adjustment
n
Perform the adjustment in Sections 2-2-1 to 2-2-8
continuously.
2-2-1. Read of Data in EEPROM
1. Display the adjustment mode window referring to
Section 2-1-2.
2. Click the [Start] button on the adjustment mode
window.
The message box below is displayed.
Yes
3. Click the [No] button and start the read of data in
EEPROM.
The message box below is displayed when read
operation is completed.
n
Message "Load Setup File Open fail. Values are not
Change" is displayed when you click the [Yes]
button.
Press the Enter key, delete the message, and return to
step 2.
SNC-CS50N/CS50P
No
4. Switch S651 on the PR-291 board to the rear position
of this unit.
Front (Lens) position
5. Restart this unit and wait for about 30 seconds.
6. Switch S651 on the PR-291 board to the front position
of this unit.
Front (lens) position
7. Click the [OK] button.
S651
Rear position
S651
Rear position
2-5 (E)