MASTER SETTINGS PROGRAMMING CONTINUED
• auxiliary 1 / auxiliary 2: Contains settings for programming up to two auxiliary relay outputs. There are three types of relays that
can be programmed:
• Cycle Based: The relay will turn on when the valve moves to the specified regeneration cycle steps. To program, select each cycle
step button for which the relay should turn on.
• Time Based: The relay will turn on and off at up to two specified start and end times. If water saving regeneration is on, this is not
an available option.
• Volume Based: The relay will turn on when the valve has treated a specified volume of water. Duration can be set for up to two
hours.
• Alarm Based: The relay will turn on when the specified alarm condition (or any alarm condition) is met. The relay will turn off when
the alarm is cleared.
Meter Screen
From the main Master Settings screen press the meter button to display the Meter screen.
• meter type: Contains settings for the type of meter installed with the system.
• generic: A generic option is available if the installed meter does not match any other selection. Requires setting the number of
pulses per volume to ensure proper metering.
• emergency regen: When on, the emergency regen feature causes a regen to occur immediately when 105% or greater of the
capacity (e.g., volume plus reserve) is used.
Continuous Flow Detect Screen
From the Meter screen press
48 • PENTAIR INTELLIWATER CONNECTED WATER SOFTENER
to display the Continuous Flow Detect screen.