Advertisement

Quick Links

FILTRATION & PROCESS
5730 NORTH GLEN PARK ROAD, MILWAUKEE, WI 53209
P: 262.238.4400 | 800.279.9404
www.pentairaqua.com
Tools and Fittings Required
• Pipe Cutter
• Tubing Cutter
• File
• Pliers
• Tape Measure
• Soldering Tools
• Lead Free Solder
• Bucket
• Towel
• PTFE Pipe Tape
• Adjustable Wrench
• Tube 100% Silicone Grease
Tested and Certified by WQA to NSF/
ANSI Standard 44 & 372 for softener
performance & lead free compliance and
CSA B483 .1 .
For further operating, installation, maintenance,
parts or assistance:
Call Technical Service at:
800.297.9404
PRF26K, PRF34K, and PRF40K
Water Softening System
INSTALLATION INSTRUCTIONS
English . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 2-19
Repair Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 14
Manual de Sistema ablandador
de agua
INSTRUCCIONES DE INSTALACIÓN
Español . . . . . . . . . . . . . . . . . . . . . . . . . . Páginas 20-37
Piezas de repuesto . . . . . . . . . . . . . . . . . . . . . Página 32
Manuel
Adoucisseur d'eau
INSTRUCTIONS D'INSTALLATION
Français . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 38-55
Piéces de Rechange . . . . . . . . . . . . . . . . . . . . . Page 50
Herramientas y accesorios
necesarios
• Sierra para cortar tuberías
• Cortatubos
• Lima
• Pinzas
• Cinta métrica
• Herramientas para soldar
• Soldador libre de plomo
• Cubeta
• Toalla
• Cinta de PTFE para tubería
• Llave ajustable
• Tubo de grasa 100% de silicona
Probado y certificado por la WQA
según la norma 44 y 372 de NSF/ANSI
por el desempeño del suavizador y el
cumplimiento del no contenido de plomo
y CSA B483 .1 .
Para obtener más información sobre el
funcionamiento, la instalación, el mantenimiento,
las piezas o para obtener asistencia:
Comuníquese con el Servicio de atención
800.297.9404
al cliente al:
Outils et accessoires requis
• Coupe-tuyau
• Coupe-tube
• Lime
• Pince
• Mètre ruban
• Outillage de brasage
• Brasure sans plomb
• Seau
• Serviette
• Ruban pour tuyau en PTFE
• Clé ajustable
• Graisse de silicone à 100 %
pour tube
Testé et certifié par WQA conforme
à la norme 44 et à la norme 372 de
NSF/ANSI pour la perfomance des
adoucisseurs et pour la conformité à
l'exemption de plomb et CSA B483 .1 .
Pour de tout autre renseignement concernant
le fonctionnement, l'installation ou l'entretien:
Appelez le service à la clientèle en com-
posant le : 800.297.9404

Advertisement

Table of Contents
loading

Summary of Contents for Pentair PRF34K

  • Page 1 PRF26K, PRF34K, and PRF40K FILTRATION & PROCESS Water Softening System 5730 NORTH GLEN PARK ROAD, MILWAUKEE, WI 53209 P: 262.238.4400 | 800.279.9404 INSTALLATION INSTRUCTIONS www.pentairaqua.com English . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 2-19 Repair Parts .
  • Page 2: Table Of Contents

    5 . Brine Line Tubing with End Inserts grounding is maintained . (shipped inside the Brine Well #10) 6 . Drain Line Tubing 7 . Tubing Clamp 8 . Wall Transformer 9 . Instruction Manual 10 . Brine Well 2 • PRF26K, PRF34K, and PRF40K...
  • Page 3 • Always make modifications to house plumbing first. Connect to valve last . • Plastic parts and O-rings may be damaged by heat and solvents . When constructing plumbing connections allow heated parts to cool and protect parts from solvents . PRF26K, PRF34K, and PRF40K • 3...
  • Page 4: Location Selection

    25" W x 15" D 25" W x 15" D 26" W x 15" D • Room to access equipment for maintenance and adding Space Requirements salt to tank . Shipping Weight 78 lbs 95 lbs 110 lbs 4 • PRF26K, PRF34K, and PRF40K...
  • Page 5 . If any parts are damaged or missing, contact your supplier . WARNING: When handling the media tank do not turn it upside down or drop on its side. When the carton is first opened, the softener will be standing upright . PRF26K, PRF34K, and PRF40K • 5...
  • Page 6 Outside Faucet Faucet Hot Water Grounding Soft Water Outlet Strap Hard Water Bypass Drain Line Water Heater Softener Brine Tank Over ow Drain Laundry Tubs Pump Meter Floor Drain Figure 4 Softened Water Flow 6 • PRF26K, PRF34K, and PRF40K...
  • Page 7: Water Line Connection

    . Service or routine maintenance procedures may also only 100% silicone grease products when require that the system is bypassed . installing any plastic valve. Non-silicone grease may cause plastic components to fail over time. PRF26K, PRF34K, and PRF40K • 7...
  • Page 8: Drain Line Connection

    40 psi (2 .76 bar) . Elevation can increase by 2 feet (61 cm) for each additional 10 psi ( .69 bar) of water pressure at the drain connector . 8 • PRF26K, PRF34K, and PRF40K...
  • Page 9: Control Operation & Layout

    4 . Hand tighten the nut until the connection is tight . NOTE: All other programmed parameters are stored in the flash memory and are retained during power outages. Flash memory retention is 100 years. Figure 11 PRF26K, PRF34K, and PRF40K • 9...
  • Page 10: Programming

    Figure 15 Step 3 Programming is complete. Figure 13 Step 1 NOTE: During programming if a button is not pushed for 5 seconds, the control returns to the normal operation mode and displays the hour of day. 10 • PRF26K, PRF34K, and PRF40K...
  • Page 11: Automatic Recharge

    AUTOMATIC RECHARGE The PRF26K, PRF34K, and PRF40K use an internal water meter that counts the gallons used . When the recharge setpoint (gallons of water treated) is reached, the unit will recharge . The setpoint depends on the capacity setting used (HE or HC) and the hardness of the water .
  • Page 12: Start-Up

    “not in bypass” (normal operation) ___ Sanitize the softener? position . ___ Add salt pellets to the salt storage tank? ___ Program the control correctly to meet your needs? ___ Start a recharge? 12 • PRF26K, PRF34K, and PRF40K...
  • Page 13: Care And Use Of Your Brine Tank

    9999 cubic foot . max value stored 65,535 . Average water usage for day 3 Average water usage for day 4 Average water usage for day 5 Average water usage for day 6 PRF26K, PRF34K, and PRF40K • 13...
  • Page 14: Tank Assembly

    D ......... Conditioning Resin 14 • PRF26K, PRF34K, and PRF40K...
  • Page 15: Valve Assembly

    D ....4001926 ..607 Control PRF26K ..4001885 ..607 Control PRF34K .
  • Page 16: Brine Well Assembly Ch15675

    4 ... 1 ..4001983 ..Tubing, 12 Foot, 1/2" ID, Drain Line, w/ Clamp 16 • PRF26K, PRF34K, and PRF40K...
  • Page 17: Troubleshooting

    Remove and clean meter . Water hammer Air in media tank . Check all salt line connections for air leaks . Tighten to stop air leaks . Air check not sealing . Clean air check assembly . PRF26K, PRF34K, and PRF40K • 17...
  • Page 18 TROUBLESHOOTING continued Flapper Positions When the control cover is removed the flappers and camshaft are visable (Figure 18) . Injector Refill Control Figure 18 18 • PRF26K, PRF34K, and PRF40K...
  • Page 19: Performance Data Sheet

    & lead Seller: ________________________________________________ Date: free compliance and _________________________ CSA B483 .1 . Buyer: ________________________________________________ Date: _________________________ 10/17/2014 PENTAIR FILTRATION & PROCESS 5730 NORTH GLEN PARK ROAD MILWAUKEE, WI 53209 P: 262.238.4400 | 800.279.9404 PRF26K, PRF34K, and PRF40K • 19...

This manual is also suitable for:

Prf26kPrf40k

Table of Contents