Start-Up Instructions/Flushing And Conditioning - Pentair INTELLIWATER PNR-POE1-XTR3-01 Installation And Operation Manual

Table of Contents

Advertisement

START-UP INSTRUCTIONS/FLUSHING AND CONDITIONING

The water softener should be installed with the inlet, outlet, and drain connections made in accordance with the manufacturer' s
recommendations, and to meet applicable plumbing codes.
1. Program the valve control according to instructions shown in this manual. See page 14 for Programming Quick Start.
2. Start an immediate regeneration by holding the Extra Cycle button for five (5) seconds. Position the valve to backwash.
Ensure the drain line flow remains steady for 10 minutes or until the water runs clear.
3. Position the valve to the brine / slow rinse position. Ensure the unit is drawing water from the brine tank (this step may
need to be repeated).
4. Position the valve to the rapid rinse position. Check the drain line flow, and run for five (5) minutes or until the water runs clear.
5. Position the valve to the start of the brine tank fill cycle. Ensure water goes into the brine tank at the desired rate.
The brine valve drive cam will hold the valve in this position to fill the brine tank for the first regeneration.
6. Replace control cover.
7. Put salt in the brine tank.
Notice
Do not use granulated or rock salt.
PENTAIR INTELLIWATER CONNECTED WATER SOFTENER • 11