Summary of Contents for Pentair PCFE40P12

  • Page 1 For the installation, operation and service of PCFE40P12 PCFE54P12 Should you the installer or owner be unfamiliar with the correct installation or operation of this type of equipment you should contact the distributor/manufacturer for the correct advice before proceeding with the installation or operation of this product.
  • Page 2: Table Of Contents

    4.2 Installation Preparation ..................11 4.3 Installation Steps ....................11 5. Operating Instructions ....................14 5.1. Commissioning and Setting ..................14 5.2. Accessing History Values ..................19 5.3. Error Diagnosis and Troubleshooting ..............20 6. Terms and Conditions of Warranty ................22 7. Maintenance Records ....................23 _________________________________________________________________________________________________________________________________________ Copyright© Pentair...
  • Page 3: Precautions And General Notes

    • Do not leave the filter system unused for an extended period. Please turn off the water supply valve if the filter system is not used for an extended period. After an extended period of non-usage, please rinse the filter system thoroughly before use. _________________________________________________________________________________________________________________________________________ Copyright© Pentair...
  • Page 4: Parts Included

    1. Carbon filter with automatic control valves 2. Inlet and outlet connector kit 3. Drain connector kit 4. Power adapter 5. Owner’s Manual 6. Drain tubes Owner’s Manual 1620 62.99 11.02 11.02 PCFE40P12 Installation Schematic (Unit: mm) PCFE54P12 Installation Schematic (Unit: mm) _________________________________________________________________________________________________________________________________________ Copyright© Pentair...
  • Page 5: Product Information

    ________________________________________________________________________________________________________________________________________ 3.1. Product Features The Pentair PCFE40P12 and PCFE54P12 carbon filters use chlorinated city water as the inlet water and effectively remove organic pollutants and residual chlorine content. Since these carbon filters use Chlorinated city water as the inlet water, they are suitable for filtration treatment of potable water in places with high daily water demand such as homes, hotels, guesthouses and restaurants.
  • Page 6: Schematic Diagrams

    Outlet Drain Media Tank Riser Tube Activated Carbon Gravel Electrical Control Diagram 220VAC 12VAC Power Transformer Socket 1 Motor LCD Display Socket 2 Optical Sensor Button 1 Button 2 Button 3 Button 4 Flow Socket 3 Meter _________________________________________________________________________________________________________________________________________ Copyright© Pentair...
  • Page 7 VALVE LAYOUT – 363TC Inlet Outlet 1” BSP 1” BSP Drain 1/2” Display Backwash Recycle Duration Time Button Button Button Cleaning Cycle Interval/Days Button Remove Cover Delayed Cleaning Cycle Indicator Flow Diagrams SERVICE BACKWASH _________________________________________________________________________________________________________________________________________ Copyright© Pentair...
  • Page 8: Introduction To Main Parts

    FAST RINSE 3.4. Introduction to Main Parts Part Name Material Specification Quantity Granular Black granular 3 ~ 400 mesh PCFE40P12 Model: 10kg Activated Carbon activated carbon PCFE54P12 Model: 16kg Gravel Gravel 3 ~ 5 mm Copper-zinc alloy Diameter: 0.149-2mm PCFE40P12: 500g...
  • Page 9: Installation Instructions

    • As much as possible, reduce the length and curvature of the drain line. Always allow an air gap between the drain line and the wastewater to prevent the possibility of wastewater being back-siphoned into the carbon filter. No valve of any type should be installed along the drain line. _________________________________________________________________________________________________________________________________________ Copyright© Pentair...
  • Page 10 • Under normal circumstances, it is recommended that KDF, granular activated carbon and gravel be replaced when the rated system capacity for treatment of chlorinated city water is reached. Please contact your local Pentair authorized distributor for replacement of KDF, granular activated carbon and gravel.
  • Page 11: Installation Preparation

    Determine the installation position of the carbon filter and lay the connecting pipes to match the various diameters of the three openings of the carbon filter. 4.00” (101.60 mm) .75” (19.05 mm) 2.00” (50.80 mm) 2.00” (50.80 mm) Inlet Outlet 1” BSP 1” BSP Drain 1/2” _________________________________________________________________________________________________________________________________________ Copyright© Pentair...
  • Page 12 Connect the connector kit to the water supply system: Wrap the ends of the connector kit with Teflon tape; attached the connector kit to the incoming pipe; the carbon filter system is then connected to the other end of connector kit; the connection is secured with the supplied U-clip. Connector kits _________________________________________________________________________________________________________________________________________ Copyright© Pentair...
  • Page 13 WARNING: Never insert drain line directly into a drain, sewer line, or trap (Figure above Drain Line Connection). Always allow an air gap between the drain line and the wastewater to prevent the possibility of sewage being back-siphoned into the filter. _________________________________________________________________________________________________________________________________________ Copyright© Pentair...
  • Page 14: Operating Instructions

    7. The hourglass is displayed when the motor is running. NOTE: During normal operation (Service mode) the display will show the current time of the day with the colon (double dots) blinking. This will alternate with a display of the – filtered water volume. _________________________________________________________________________________________________________________________________________ Copyright© Pentair...
  • Page 15 4 minutes 18 - 21 minutes 5 minutes 22 - 25 minutes 6 minutes 26 - 29 minutes 7 minutes 30 - 35 minutes 8 minutes 36 - 40 minutes 9 minutes 41 - 50 minutes 10 minutes _________________________________________________________________________________________________________________________________________ Copyright© Pentair...
  • Page 16 Press and hold the button to rapidly advance the value. Release the button when the desired value is displayed. The value will be stored in memory after five seconds. Range: 8 hours (0.3 days) - 30 days; 0 to disable Default: 0 (disabled) _________________________________________________________________________________________________________________________________________ Copyright© Pentair...
  • Page 17 Initial Startup settings The description above guides the system parameters. • Time of day: current time • ’Backwash Duration’ and ‘Cleaning Cycle Interval’ be set according below table. PCFE40P12 TSS(NTU) Cleaning Cycle Interval(t) Backwash Duration(min) <1 1.0-2.0 >2...
  • Page 18 Upon completion of the above initial power up steps, the carbon filter needs to be put into operation. Please follow the following procedures strictly to perform commissioning. (This process is to be performed by the Pentair authorized distributor): • Set the “Time of Day”, “Backwash Duration” and “Cleaning Cycle Interval” in accordance with actual requirements.
  • Page 19: Accessing History Values

    Press ”Backwash Duration” to display the value. Some history values may have up to four digits. Press ”Backwash Duration” to display the first two digits of the value. Press “Cleaning Cycle Interval” to display the last two digits. _________________________________________________________________________________________________________________________________________ Copyright© Pentair...
  • Page 20: Error Diagnosis And Troubleshooting

    Cancel the bypass state. flow controller fails The meter cable is detached from Reconnect the meter cable to to show the operating the valve. the valve. flowrate The meter is blocked by debris. Disassemble and clean the meter. _________________________________________________________________________________________________________________________________________ Copyright© Pentair...
  • Page 21 Home and connected to wire. position: Inspect for debris in the camshaft slots. If motor continues to rotate indefinitely, replace the following components in this order: 1. Motor Assembly. Optical Sensor 2. Control _________________________________________________________________________________________________________________________________________ Copyright© Pentair...
  • Page 22: Terms And Conditions Of Warranty

    6. Warranty does not cover for all consumables, such as filter element and materials, in water treatment equipment. 7. Pentair reserves the right to charge a certain service fee for maintenance or repair service provided on-site in remote areas. _________________________________________________________________________________________________________________________________________...
  • Page 23: Maintenance Records

    7. MAINTENANCE RECORDS ________________________________________________________________________________________________________________________________________ MAINTENANCE DATE CAUSE OF ERROR REPLACEMENT PART PERSONNEL _________________________________________________________________________________________________________________________________________ Copyright© Pentair...
  • Page 24 33/4 Rama 9 Road, Huaykwang Bangkok 10310, Thailand Tel: +662 1681092 © Information contained here-in remains the property of Pentair. Any reproduction, display, publication, modification or distribution is strictly prohibited without the prior written permission of Pentair. Disclaimer: Every endeavour has been made to publish the correct details in this manual. No responsibility will be taken for errors, omissions or changes in product descriptions, specifications.