Sec. 8 Clearance between needle and shuttle

Note: Make this checking before checking "Needle timing to shuttle"
Checking:
1. Remove needle plate, bobbin case and face cover.
2. Set test mode at 1.
3. Shift shuttle hook at the rear of needle by turning hand wheel.
Check to see if needle clearance to shuttle is within 0.05 to 0.15 mm.
0.05~0.15mm
0.05~0.15mm
At left position
At right position
Shuttle
0.05~0.15mm
At left position
At right position
Adjustment:
1. Turn screw to either direction as illustrated and adjust needle position by moving support
shaft back and forth.
To decrease clearance, turn screw to counter-clockwise.
- 19 -