INSTALLATION MANUAL
GV60 Outdoor Fireplace Conversion Kit
Use with Valor Zero Clearance heater models 530, 534, 650, 1000, 1100, 1150, 1400,
1500, 1600, 1700, 1800 and Insert heater models 700, 738K, 739, 780, 785, RF24KB,
RF24JD installed into existing approved solid-fuel burning fireplaces having weather
protection as specified in this manual.
General notes regarding conversion
This manual contains instructions for adapting natural
gas or propane models listed above for use outdoors.
For the purpose of this manual the term "outdoor"
means installed outside of the insulated building
envelope within a weatherproof enclosure or existing
solid-fuel burning fireplace having a minimum required
overhang. The outdoor space may be attached or free
standing to the main/primary structure and may or may
not include walls. See page 6 for further information
regarding locating your outdoor fireplace.
Use this manual in conjunction with the installation
manual supplied with the appliance. The outdoor
fireplace must be permanently situated and connected
to a fixed piping system and must not be portable.
Notes
• No electrical accessories (fans, lighting or wifi) per-
mitted when adapting the appliance for outdoor use.
• Any of the optional available trims and fronts may
be used in the outdoor environment including
optional HeatShift components although please
note that some fading or corrosion may occur due to
environmental conditions. Cast iron fronts are not
recommended outdoors.
• Thermostatic controls are not allowed for outdoor
fireplaces. Use the wall switch supplied with the
appliance or when not supplied, order an optional
RBWSK Remote battery and wall switch kit to control
the appliance. Do not use the thermostatic remote
controled handset supplied with the appliance!
DO NOT USE thermostatic handset supplied with
appliance when installing outdoors!
X X
4006080-04
© Copyright Miles Industries Ltd., 2021.
GV60CKO
 WARNING
This conversion kit shall be installed by
a qualified service agency in accordance
with the manufacturer's instructions and
all applicable codes and requirements
of the authority having jurisdiction. If
the information in these instructions is
not followed exactly, a fire, explosion
or production of carbon monoxide may
result causing property damage, personal
injury or loss of life. The qualified service
agency is responsible for the proper
installation of this kit. The installation
is not proper and complete until the
operation of the converted appliance is
checked as specified in the manufacturer's
instructions supplied with the kit.
Use this manual in conjunction with the
installation manual supplied with the
appliance.
LEAVE THIS MANUAL WITH THE HOMEOWNER.
 WARNING
Electrical shock hazard - Do not install
electrical accessories (fans, lighting, wifi)
when converting the appliance for use
outdoors.
USE 1265WSK or RBWSK (appliance installed under
overhang)
1265WSK–
Wall Switch
Remote Batteries &
RBWSK–
U P
FIRE PL AC E
BAT TERY
ACC ESS
ON-OFF
Wall Switch Kit
ACC È S
P IL E S
DOWN
DU FOYER

Advertisement

Table of Contents
loading

Summary of Contents for Valor GV60CKO

  • Page 1 GV60CKO GV60 Outdoor Fireplace Conversion Kit Use with Valor Zero Clearance heater models 530, 534, 650, 1000, 1100, 1150, 1400, 1500, 1600, 1700, 1800 and Insert heater models 700, 738K, 739, 780, 785, RF24KB, RF24JD installed into existing approved solid-fuel burning fireplaces having weather protection as specified in this manual.
  • Page 2: Kit Contents

    Kit Contents • 1 GV60 outdoor receiver with conformal coating— to resist weather—part no. 4005111 • 1 Overlay conversion label—part no. 4006081 • 1 Outdoor Lighting Instructions card—part no. 4005169 G6R-R3AMC— Conversion label and Outdoor receiver Lighting Instructions Replace the existing receiver 6.
  • Page 3 “off” position. Upon ensuring the fireplace cannot be turned on you Your Valor outdoor gas fireplace will tolerate moderate can then apply a weather protective cover over the front amounts of water on an occasional basis but is not of the fireplace to help preserve the finish and further designed to be waterproof.
  • Page 4: For Your Safety Read Before Lighting

    Lighting Instructions for Outdoor Fireplace Use FOR YOUR SAFETY, READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a re or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand, or wall switch. Follow these instructions exactly. To save gas, turn the pilot o when not using the appliance for a prolonged period of time.
  • Page 5 Location Top View (typical) For the purposes of this installation manual the term “outdoor” means Min. required installed outside of the insulated building overhang envelope within a weatherproof enclosure Outdoor fireplace or existing solid-fuel burning fireplace Min. required weatherproof installed in overhang in front and at sides of having a minimum required overhang.
  • Page 6 Typical Location Continuous insulated building envelope and weatherproof INSIDE membrane is NOT interrupted by fireplace installation INSIDE Min. weatherproof overhang See appliance manual and in front and at sides page 8 of Weatherproof enclosure or this manual for OUTSIDE allowable vent existing solid-fuel burning terminal location fireplace...
  • Page 7 Combustible Overhang—Left Side View All models Note: Use of the optional HeatShift System Kits ® affects mantel and hearth clearances. See instructions in fireplace’s Installation manual. Combustible Overhang Min. required weatherproof overhang Do not put furniture or objects within 36” (914 mm) of front of appliance Bottom of appliance not to scale...
  • Page 8 (either permanent or temporary cover) easily accessible require a terminal guard such as the at least 30% of the total perimeter wall area surrounding Valor 658TG or 845TG. the outdoor space must be openings. Min. 72” Max. 72”...
  • Page 9 The Company does not allow anyone to extend, b) Installation and maintenance must be performed alter or modify this warranty and assumes no...
  • Page 10 GV60CKO GV60 Conversion pour foyer extérieur Utilisez avec les foyers Valor à dégagement zéro (ZC) 530, 534, 650, 1000, 1100, 1150, 1400, 1500, 1600, 1700, 1800 et encastrables 700, 738K, 739, 780, 785, RF24KB, RF24JD installés dans un foyer à combustibles solides certifié existant protégés des intempéries tel que décrit dans le présent guide.
  • Page 11: Contenu Du Kit

    Contenu du kit • 1 Récepteur pour l’extérieur GV60 avec revêtement comforme—résistant aux conditions atmosphériques—pièce n 4005111 G6R-R3AMC—Récepteur Étiquette de conversion • 1 Étiquette de conversion—pièce n 4006081 extérieur et consignes d’allumage • 1 Carte de consignes d’allumage pour l’extérieur— pièce n 4005169 5.
  • Page 12 Le fait de mettre le foyer hors service et de le couvrir durant la période ou il n’est Votre foyer extérieur Valor tolérera, à l’occasion, une pas utilisé prolongera aussi la couleur des finitions. quantité modérée d’eau mais il n’est pas imperméable Mise hors service pour une période...
  • Page 13: Que Faire Si Vous Sentez Une Odeur De Gaz

    Consignes d’allumage pour foyer utilisé à l’extérieur POUR VOTRE SÉCURITÉ LIRE AVANT D’ALLUMER MISE EN GARDE : Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 14 Emplacement Vue du dessus typique Aux fins de ce guide d’installation, le terme “extérieur” désigne l’installation Surplomb Surplomb à l’épreuve en dehors de l’enveloppe d’isolation minimum exigé des intempéries exigé en avant et de chaque d’un édifice dans un espace à l’épreuve côté...
  • Page 15 Emplacement typique INTÉRIEUR Enveloppe isolante continue de l’édifice et membrane à l’épreuve des intempéries NE SONT PAS interrompues par l’installation du foyer Voir guide du Taille minimale du surplomb à foyer et page 17 l’épreuve des intempéries à l’avant et de chaque côté du foyer de ce guide pour emplacements EXTÉRIEUR...
  • Page 16 Surplomb combustible—Vu du côté gauche Tous les modèles Note : L’utilisation du Système Heat- Shift optionnel affecte les dégage- ments aux manteau et dalle protec- trice. Consultez le Guide d’installation HeatShift fourni en appendice du Guide d’installation du foyer. Surplomb combustible Surplomb minimum à...
  • Page 17 • Lorsqu’une sortie d’évacuation se termine sous une • La sortie d’évacuation doit être couverte par une grille couverture (permanente ou temporaire), au moins de protection telle que la Valor 658TG ou la 845TG lorsqu’accessible—à moins de 7 pi (2,13 m) du sol. Min. 72”...
  • Page 18 Garantie Valor - installation extérieure Garantie Valor installation extérieure ® Si vous éprouvez des di cultés avec votre appareil, veuillez contacter immédiatement votre détaillant ou fournisseur. Ne tentez jamais de réparer cet appareil par vous-même. Les garanties énoncées au paragraphe 1 s’appliquent uniquement au propriétaire initial de cet appareil;...

This manual is also suitable for:

Gv60

Table of Contents