TD350 Series VFD
Function
Name
code
Corresponding
P26.46
AO3 output of
upper limit
AO3 output filter
P26.47
time
P26.48–
Reserved
P26.52
variables
P28 group Master/slave control functions
Master/slave
P28.00
mode selection
Master/slave
communication
P28.01
data selection
Master/slave
P28.02
control mode
P28.03 Slave speed gain 0.0–500.0%
P28.04 Slave torque gain 0.0–500.0%
Master/slave
P28.05
mode 2 speed
Detailed parameter description
Setting range of P26.41: 0.00V–10.00V
Setting range of P26.42: 0.000s–10.000s
Setting range of P26.43: -100.0%–P26.45
Setting range of P26.44: 0.00V–10.00V
Setting range of P26.45: P26.43–100.0%
Setting range of P26.46: 0.00V–10.00V
Setting range of P26.47: 0.000s–10.000s
0–65535
0: The master/slave control is invalid
1: This machine is a master
2: This machine is a slave
0: CAN
1: Reserved
Ones: Master/slave running mode selection
0: Master/slave mode 0
(The master and slave adopt speed control and
maintains the power balance by droop control)
1: Master/slave mode 1
(The master and slave must be in the same type of
vector control mode. The master is speed control,
and the slave will be forced to be in the torque
control mode.
2: Master/slave mode 2
Start in the slave first speed mode (master/slave
mode 0) and then switch to torque mode at a
certain frequency point (master/slave mode 1)
Tens: Slave start command source selection
0: Follow the master to start
1: Determined by P00.01
Hundreds: Slave transmitting/master receiving data
enable
0: Enable
1: Disable
0.00–10.00Hz
-237-
Function parameter list
Default
Modify
value
○
10.00V
○
0.000s
○
0
◎
0
◎
0
◎
0x001
○
100.0%
○
100.0%
○
5.00Hz