UNITY 500
3 - Carrier Search
4 - No COMPEL
5 – (No COMPEL) Header Seek
6 – (No COMPEL) Header Search
time: Time-out value in HH:MM:SS format. Minimum value is 00:00:00 and maximum
value is 00:00:30 for fade and 4660:20:15 for all others.
Timeout.source is set to time. See Section
SNR alarm_level margin_offset
alarm_level: Units of dB with range from 2.0 - 7.0 and can have one decimal place.
margin_offset: Units of dB with range from 1.0 - x and can have one decimal place. Sum
of alarm_level and margin_level cannot exceed 12.0.
Sets SNR Alarm Level and Margin Offset accordingly.
TEMP settings time
settings:
time: Length of insert in HH:MM:SS format. Valid range is 00:00:00 to 18:00:00.
Does temporary insert per
TEMPCH location time
location: Value from 1 - 48 indicating location in settings table.
time: Same as for TEMP.
Unit sets it temp settings to those retrieved from the settings table according to location.
See TEMP command.
UNMUTE [source][source]
source:Same as the MUTE command.
Identical to MUTE except specified services are unmuted.
A.1.2

Local Control Commands

H [command]
command: Any of the terminal command names (H, R, TEMP, etc.).
If an 'H' or any invalid command beginning with an 'H' is entered and command is
omitted, the whole help screen will be displayed, consisting of a list of all currently
available commands and a brief description of each listing. If an 'H' or any invalid
command beginning with an 'H' is entered and command is a valid User Command Name,
then detailed help for command is displayed.
See Section
3.1
.
Table 8
(Page 34). Unit sets its temp settings to settings.
Page 41 of 56
3.3
(Page 35) for an explanation of timeouts.