INSTALLATION
y Remove the protective film.
y Adjust the 4 feet if necessary.
y If optional signage kit, position the magnetic signs facing the chosen waste chute hole.
y Place a bag on each collector and maintain it using the elastic strap provided. DO NOT WIND THE BAG AROUND THE WASTE CHUTE HOLE COLLAR.
y Install the collector under the table by pushing it completely into its housing.

WEIGHING OPTIONS

y Not authorised for commercial transactions.
y Connected weighing option : Turning on and assistance are provided by IDEOLYS .
y Weighing option with direct display : The direct display option shows the weight of the waste in real time.
A total weight function allows you to add several weighings, when changing bags and to display the total at the end of service. This option can be used only
with collectors for bags and the Organic waste bucket.
Interface :
y Turning it on :
- Use only suitable BOURGEAT collectors or buckets. Install the bag in the collector and maintain it with the strap provided. Never wind it around the
removable collar of the waste chute hole. Place the empty container fully into its housing.
- Turn it on by pressing ON.
- Press TARE. The display should indicate 0.00.
- The system is ready for use.
- Press TARE again each time the container is changed.
y Total function :
- To add the current weight to memory (before changing the container for example) press M+.
- To display the total, press MR. The number of weighings is displayed, then the total weighed.
- To erase the contents of the memory, press the MR/MC button for several seconds.
- Warning, the memory is erased when the device is turned off.
y Characteristics :
- Display resolution is 10g. Weighing accuracy is ±40g.
- Maximum weight per weighing module: 50kg.
- Backlit screen with automatic switch-off
- Operates on a rechargeable battery (about 40 services) on with mains power. Power pack supplied. Time required for a total charge is about 14h.
- Main power 230V-240V 0.5A.

RECOMMENDATIONS FOR USE

y For correct operation of the weighing :
- Use only suitable BOURGEAT collectors or buckets.
- Ensure that the bag is correctly installed.
- Never wind it around the removable collar of the waste chute hole.
- Place the empty container fully into its housing.
- Tare each time the collector or bucket is changed.

MAINTENANCE

y Do not clean the units using a jet.
y Wooden parts: use soapy water and a sponge.
y General information on stainless steel : The term "stainless steel" can cause some confusion. It is steel which "resists" to corrosion in certain conditions.
Any type of stainless steel can be corroded:
- austenitic, e.g. "stainless steel 304" also called 18/10.
- ferritic, e.g. "F17" or "F18TNb".
Resistance to corrosion of stainless steel results from the existence of a passive layer of chromium oxide which is renewed spontaneously when in contact
with the air. Any phenomenon interfering with the creation of this layer is likely to cause corrosion.
This is why stainless steel surfaces must be regularly rid of miscellaneous contamination which may damage the level of resistance of the passive layer, and
also ensure the maintenance steps are observed. (Preparation to cleaning / cleaning / rinsing / disinfection / rinsing / drying).
Regular maintenance with extended rinsing with water is the best method to renew and maintain the passive layer.
Each of the steps linked with maintenance presents risks of damaging the passive layer: using hard water / overdosing detergents / using chlorine-based
detergents / food residue on the products / insufficient rinsing.....
Whenever corrosion appears, the element or step having led to it must be identified.
y Advice :
- maintain stainless steel surfaces clean and dry. Ensure there is a sufficient flow of air.
- clean daily to remove scale, grease and any food residue. Corrosion can form under these layers by lack of air inlet.
- daily cleaning can be performed with a damp cloth. If necessary :
* use soapy water, cleaning products with low chloride content, javel-free detergents, window degreasers.
* remove hard stains with a non metallic brush (plastic material, natural bristles or stainless steel wool).
- do not scratch the surfaces with metals other than stainless steel, and more particularly, never use iron brushes.
- remove fresh rust stains with soft abrasive agents or fine emery cloth.
- for larger stains, use hot oxalic acid with a 2-3% concentration. If necessary, apply a treatment with nitric acid concentrated at 10%.
After treatment, wash thoroughly with water and wipe.
The use of acid is reserved to skilled persons and complying with regulations.
y Product to ban :
- Javel water and chlorine based products
- hydrochloric acid
- iron oxide abrasive powders.
y Cleaning the table : use soapy water and a sponge. Direct weighing option: IP42 protection.
y Collar : dishwasher safe.
y Collectors : can be washed with a stream.
y Signage option : wash the signs only with a sponge and soapy water. Do not use an abrasive sponge. Not dishwasher safe.
TABLES WITH WEIGHING OPTIONS
This equipment carries the recycling symbol in accordance with Directives 2011/65/CE and 2012/19/CE relating to Waste Electrical or Electronic Equipment
(DEEE or WEEE) At the end of its working life the equipment should be recycled in accordance with the regulations that are in force in the country of its
installation.
ENGLISH
OFF button: long press = turns off.
UNIT button: changes the unit (kg/lb).
MR/MC button: Displays the total weight and the number of measure-
ments/Erases the memory with a long press.
M+ button: adds the current weight to memory.
TARE button: resets the display.
ON button: turns on.