Atlantic geolia 13 Installation And Operating Manual

Atlantic geolia 13 Installation And Operating Manual

Ground source heat pump water/water and brine/water
Hide thumbs Also See for geolia 13:
Table of Contents

Advertisement

Quick Links

atlantic geolia
Document n° 1641-17 ~ 23/10/2020
FR
EN
NL
DE
IT
Ground source heat pump
water/water and brine/water
atlantic geolia 13
atlantic geolia 17
Installation and
operating manual
intended for professionals
To be saved for
future consultation
atlantic-comfort.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the geolia 13 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Atlantic geolia 13

  • Page 1 Document n° 1641-17 ~ 23/10/2020 Ground source heat pump water/water and brine/water atlantic geolia 13 atlantic geolia 17 Installation and operating manual intended for professionals To be saved for future consultation atlantic-comfort.com...
  • Page 2: Table Of Contents

    Ground source heat pump atlantic geolia 13 - 17 Contents Description of the unit ......4 Packaging .
  • Page 3 Ground source heat pump atlantic geolia 13 - 17 Controller ........28 Description of the display .
  • Page 4: Description Of The Unit

    Ground source heat pump atlantic geolia 13 - 17 Packing list Heat pump (HP) Hydraulic unit Hydraulic accessories kit Model Code Model Code atlantic geolia 13 522973 023423 074085 atlantic geolia 17 522974 023424 Optional equipment Scope of application This heat pump provides: •...
  • Page 5: Specifi Cations

    Ground source heat pump atlantic geolia 13 - 17 Specifi cations Model atlantic geolia Nominal heating performances (brine temperature/ heating circuit temperature) Heating capacity +10°C +7°C / +30°C +35°C - Floor heating system 16.78 22.13 0°C -3°C / +30°C +35°C - Floor heating system 12.63...
  • Page 6 Ground source heat pump atlantic geolia 13 - 17 Heating Circuit (water only) Circuit Chauffage (en eau pure) 1 mbar = 10 mmCE = 100 Pa m /h Brine Circuit (water only) Circuit Capteur (en eau pure) 1 mbar = 10 mmCE = 100 Pa m /h fi...
  • Page 7 Ground source heat pump atlantic geolia 13 - 17 Right side view Front view Left side view 13 10 Caption : 1 - Refrigerant unit 7 - Heating circuit safety valve 11 - Brine circuit pump (CCpt) 2 - Supply terminal block...
  • Page 8: Operation Principle

    Ground source heat pump atlantic geolia 13 - 17 Operation principle The ground source heat pump uses the energy stored • Fan-coil with integrated control system in rock, ground or water to provide heat to a building Do not use a room sensor in the area equipped with fan and to sanitary water.
  • Page 9 Ground source heat pump atlantic geolia 13 - 17 Surface Brine circuit Heat produced 20 °C Ground energy Boreholes COP 4 Caption : 1 kW HP - Heat Pump Electrical Cn - Condenser energy Cp - Compressor consumed Dt - Expansion valve Ev - Evaporator fi...
  • Page 10: Installation

    Ground source heat pump atlantic geolia 13 - 17 2 Installation Installation rules Unpacking and reservations and maintenance conditions 2.2.1 Reception The appliance must be installed and maintained by an Carefully check, in the carrier's presence, the general approved professional in accordance with the prevailing...
  • Page 11: Handling

    Ground source heat pump atlantic geolia 13 - 17 Safety transport paws 2.2.3 Handling The ground source heat pump should not be laid down  Remove safety transport paws. during transportation. Lying down transportation may damage internal pipes and compressor suspension.
  • Page 12: Brine Circuit Installation

    Ground source heat pump atlantic geolia 13 - 17 Brine circuit Installation 2.5.2 Surface Brine circuit 2.5.1 Dimensioning of the brine circuit • Refer to the instructions supplied with the Brine circuit kit. The Brine circuit must be sized to pass the fl ow rate and collect the calories according to the ground source HP characteristics.
  • Page 13: Ground Water

    Ground source heat pump atlantic geolia 13 - 17 2.5.4 Ground water 2.5.5 Connection of the Brine circuit The Brine circuit pump is integrated to the heat pump. - Insulate pipes inside the house to prevent condensation using supplied self-adhesive insulating tape.
  • Page 14: Installation Of The Heat Pump

    Ground source heat pump atlantic geolia 13 - 17 Installation of the Heat Pump 2.6.1 Installation precautions In accordance with EN 378-1 -2017 standard (Refrigerating systems and heat pumps - Safety and environmental requirements), the system's hydraulic unit and all refrigeration connections passing through inhabited areas must comply with the minimum room volume requirements shown hereafter.
  • Page 15: Access To The Hp Connections

    Ground source heat pump atlantic geolia 13 - 17 • Be careful not to bring fl ammable gas near by the 2.6.2 Access to the HP connections heat pump during its installation, in particular when - Remove the front panel.
  • Page 16: Hydraulic Connection Of The Heating Circuit

    Ground source heat pump atlantic geolia 13 - 17 Hydraulic connection of the heating circuit 2.7.1 General 2.7.4 Filling and venting the installation The tightness operation shall follow the plumbing state Check the pipe connection, the tightness of the of the art: connectors and the stability of the heat pump.
  • Page 17: Circulating Pump Speed Settings

    Ground source heat pump atlantic geolia 13 - 17 Circulating pump speed settings atlantic geolia 13 atlantic geolia 17 Heating Circuit Brine Circuit Heating Circuit Pump ext. in Brine Circuit Pump fi gure 14 - Recommended circulating pump speed Circulating pump stuck or blocked: If the motor is blocked, a starting procedure is launched.
  • Page 18: Electrical Connections

    Ground source heat pump atlantic geolia 13 - 17 Electrical connections • Connecting to electronic board Ensure that the general electrical power supply has been cut off before starting any repair work. Flexible wires H07RNF type (or superior quality) fl exible wire can be 2.9.1 Characteristic of the electrical supply...
  • Page 19: Overview Of All The Electrical Connections

    Ground source heat pump atlantic geolia 13 - 17 2.9.3 Overview of all the electrical connections The wiring diagram for the hydraulic unit is shown in detail on fi gure 20, page Room control unit T78 (optional) Outdoor sensor Cable 2 x 0.75 mm²...
  • Page 20: Electrical Connections Of Hp

    Ground source heat pump atlantic geolia 13 - 17 2.9.5 Electrical connections of HP Access to the connection terminals: - Remove the front panel and the right side panel of the HP. - Remove the front panel of the electrical box.
  • Page 21 Ground source heat pump atlantic geolia 13 - 17 Thermal relay HP controller User Interface Cable gland Cable gland Front view (Sensors) (Power) Starter Electrical back-up relay + Terminal blocks intermediare Electrical back-up heat exchanger safety thermostat terminal blocks Top view User Interface fi...
  • Page 22: Heat Pump Electrical Wiring

    Ground source heat pump atlantic geolia 13 - 17 2.10 Heat Pump Electrical wiring fi gure 20 - Electrical wiring - 22 - Installation and operating manual "1641 - EN"...
  • Page 23 Ground source heat pump atlantic geolia 13 - 17 • Boiler connection (optional) • Buff er (see Overall hydraulic layout page  If the boiler connection option is used, the  If the water volume of the installation is less electric boost option must be disconnected.
  • Page 24: Outdoor Sensor

    Ground source heat pump atlantic geolia 13 - 17 2.11 Outdoor sensor The outdoor sensor is required to allow correct operation of the heat pump. Consult the installation instructions on the packaging. Place the sensor on the coldest side of the building, generally the northern or north-eastern side.
  • Page 25: Commissioning

    Ground source heat pump atlantic geolia 13 - 17 2.13 Commissioning - Close the installation's main circuit breaker. When commissioning, the electrical back-up heaters are liable to start up even if the outdoor temperature at - Check that the phase-neutral polarity is respected.
  • Page 26: Venting The Brine And Heating Circuits

    Ground source heat pump atlantic geolia 13 - 17 2.13.1 Venting the Brine and Heating circuits In order to correctly vent the Brine circuit and Heating circuit, run circulating pumps in "test mode". Brine Circuit : - Set the 7700 parameter on 6 (QX5: Brine Pump).
  • Page 27: Confi Guration Of Room Thermostat (T58)

    Ground source heat pump atlantic geolia 13 - 17 2.14 Confi guration of room thermostat (T58) To confi gure the room thermostat and connect it to the appropriate heating zone: - Hold presence key; room - Hold on the presence key for more than 3 seconds.
  • Page 28: Thermostat (Optional)

    Ground source heat pump atlantic geolia 13 - 17 3 Controller User interface, Room control unit (optional) and Room thermostat (optional) User interface Auto Auto °C Remote control T75 / T78 (wireless) Room thermostat T55 / T58 (wireless) fi gure 23 - - 28 - Installation and operating manual "1641 - EN"...
  • Page 29 Ground source heat pump atlantic geolia 13 - 17 Ref. Function - Defi nitions Selecting of the DHW operating mode If the installation is fi tted with a DHW tank. (Domestic hot water) - On: Production of DHW according to the time program.
  • Page 30: Description Of The Display

    Ground source heat pump atlantic geolia 13 - 17 Description of the display Temperature control The heat pump operation is managed by the temperature control. The set temperature for the water in the heating circuit is adjusted according to the outdoor temperature.
  • Page 31 Ground source heat pump atlantic geolia 13 - 17 Heating curve slope Low temperature 1.25 radiator Boiler connection application Dynamic radiators 0.75 Heat pump application only Floor heating 0.25 Outdoor temperature °C fi gure 26 - Heating curve slope (line 720)
  • Page 32: Setting Parameters

    Ground source heat pump atlantic geolia 13 - 17 Setting Parameters 3.4.2 Setting parameters - Choose the desired level. 3.4.1 General - Scroll the menu list. Only the parameters accessible to levels: - Choose the desired menu. U - End user.
  • Page 33 Ground source heat pump atlantic geolia 13 - 17 Line Function Setting range Setting Basic or display increment setting Heating time programme, circuit 1 Pre-selection (Day / Week) Mon-Sun, Mon-Fri, Sat-Sun, Mon-Sun Monday, Tuesday, … phase On (start) 00:00... --:--...
  • Page 34 Ground source heat pump atlantic geolia 13 - 17 Line Function Setting range Setting Basic or display increment setting Time programme 5 / Cooling If the installation is fi tted with the cooling kit (Only with the cooling kit option).
  • Page 35 Ground source heat pump atlantic geolia 13 - 17 Line Function Setting range Setting Basic or display increment setting 24-hour heating limit -10 °C... 10 °C 1 °C -2 °C This function enables you partially to off set the automatic summer/winter switchover during the intermediate seasons.
  • Page 36 Ground source heat pump atlantic geolia 13 - 17 Line Function Setting range Setting Basic or display increment setting Floor curing setpoint manually 0... 95 °C 1 °C 25 °C (if line 850 = manual) This function enables you to set the custom concrete slab drying temperature. This temperature remains fi xed.
  • Page 37 Ground source heat pump atlantic geolia 13 - 17 Line Function Setting range Setting Basic or display increment setting Heating, circuit 2 Only with the 2nd circuit kit option (If the installation consists of 2 heating circuits). 1010 Comfort setpoint Reduced setpoint…...
  • Page 38 Ground source heat pump atlantic geolia 13 - 17 Line Function Setting range Setting Basic or display increment setting 1151 Floor curing setpoint manually 0... 95 °C 1 °C 25 °C (if line 1150 = manual) This function enables you to set the custom concrete slab drying temperature. This temperature remains fi xed.
  • Page 39 Ground source heat pump atlantic geolia 13 - 17 Line Function Setting range Setting Basic or display increment setting Heat pump (HP) 2816 Source temperature mini brine -30... 50 °C 1 °C -10 °C (Mini. HP evaporator temperature glycol water/Water) If water/water HP, set the parameter to 8 °...
  • Page 40 Ground source heat pump atlantic geolia 13 - 17 Line Function Setting range Setting Basic or display increment setting Supplementary source (Boiler connection) 3700 Release below outdoor temperature -50... 50 °C 1 °C 2 °C 3701 Release above outdoor temperature -50...
  • Page 41 Ground source heat pump atlantic geolia 13 - 17 Line Function Setting range Setting Basic or display increment setting Fault 6711 Reset HP No, Yes 6800 History 1 Time, Date, Error code 6802 History 2 Time, Date, Error code 6804...
  • Page 42 Ground source heat pump atlantic geolia 13 - 17 Line Function Setting range Setting Basic or display increment setting 7830 Sensor temperature BX21 module 1 -28... 350 °C 7831 Sensor temperature BX22 module 1 -28... 350 °C 7845 Input signal H2, module 1...
  • Page 43 Ground source heat pump atlantic geolia 13 - 17 Line Function Setting range Setting Basic or display increment setting 8444 Remain limit source temperature 0... 2730 h 8450 Hours run compressor 1 0... 2730 h Reset ? (no, yes) 8451 Start counter compressor 1 0...
  • Page 44 Ground source heat pump atlantic geolia 13 - 17 Line Function Setting range Setting Basic or display increment setting 8840 Hours run DHW pump 0... 2730 h Reset ? (no, yes) 8841 Start counter DHW pump 0... 199999 Reset ? (no, yes)
  • Page 45 Ground source heat pump atlantic geolia 13 - 17  Installation and operating manual "1641 - EN" - 45 -...
  • Page 46: Overall Hydraulic Layout

    Ground source heat pump atlantic geolia 13 - 17 4 Overall hydraulic layout • Confi guration 1: 1 heating circuit / Heating/cooling fl oor - 46 - Installation and operating manual "1641 - EN"...
  • Page 47 Ground source heat pump atlantic geolia 13 - 17 • Confi guration 1: heating circuit / Heating/cooling fl oor and DHW tank (with electrical back-up) Installation and operating manual "1641 - EN" - 47 -...
  • Page 48 Ground source heat pump atlantic geolia 13 - 17 • Confi guration 1: 1 heating circuit / Radiators (buff er like "hydraulic separation tank") - 48 - Installation and operating manual "1641 - EN"...
  • Page 49 Ground source heat pump atlantic geolia 13 - 17 • Confi guration 1: 1 heating circuit / Radiators & DHW tank (buff er like "hydraulic separation tank") Installation and operating manual "1641 - EN" - 49 -...
  • Page 50 Ground source heat pump atlantic geolia 13 - 17 • Confi guration 1: 1 heating circuit / Radiators (buff er like "serie tank") - 50 - Installation and operating manual "1641 - EN"...
  • Page 51 Ground source heat pump atlantic geolia 13 - 17 • Confi guration 1: 1 heating circuit / Radiators & DHW tank (buff er like "serie tank") Installation and operating manual "1641 - EN" - 51 -...
  • Page 52 Ground source heat pump atlantic geolia 13 - 17 • Confi guration 2: 2 heating circuits - 52 - Installation and operating manual "1641 - EN"...
  • Page 53 Ground source heat pump atlantic geolia 13 - 17 • Confi guration 2: 2 heating circuits and DHW tank (with electrical back-up) Installation and operating manual "1641 - EN" - 53 -...
  • Page 54 Ground source heat pump atlantic geolia 13 - 17 • Confi guration 3: 1 heating circuit & boiler connection - 54 - Installation and operating manual "1641 - EN"...
  • Page 55 Ground source heat pump atlantic geolia 13 - 17 • Confi guration 3: 1 heating circuit, DHW tank & boiler connection Installation and operating manual "1641 - EN" - 55 -...
  • Page 56 Ground source heat pump atlantic geolia 13 - 17 • Confi guration 4: 2 heating circuits & boiler connection - 56 - Installation and operating manual "1641 - EN"...
  • Page 57 Ground source heat pump atlantic geolia 13 - 17 • Confi guration 4: 2 heating circuits, DHW tank & boiler connection Installation and operating manual "1641 - EN" - 57 -...
  • Page 58: Troubleshooting

    Ground source heat pump atlantic geolia 13 - 17 5 Troubleshooting The errors may be displayed on the digital screen. Errors displayed on the HP Errors or breakdowns on the hydraulic unit are indicated by the display on the user interface.
  • Page 59: Information Displayed

    Ground source heat pump atlantic geolia 13 - 17 Information displayed Various data can be displayed when pressing the - Various data (see below). key. Designation Line Depending on the type of unit, confi guration and Floor drying current setpoint .
  • Page 60: Maintenance Of The Installation

    Ground source heat pump atlantic geolia 13 - 17 6 Maintenance of the installation Ensure that the general electrical power supply has been cut off before starting any repair work. Brine circuit checks Heating circuit checks Periodically check the brine pressure in the Brine circuit : ...
  • Page 61 Ground source heat pump atlantic geolia 13 - 17 Start Time = C Start Time Initial Voltage = B Initial Voltage Stop Time Stop Time = B fi gure 30 - Starter (factory setting) Installation and operating manual "1641 - EN"...
  • Page 62: Quick-Start Procedure

    Ground source heat pump atlantic geolia 13 - 17 7 Quick-start procedure Before switching on the Heat pump: Start-up check-list 7.1.1 Before starting-up • Sight check and hydraulic checks (see chapiter "Installation of the Heat Pump", page 14). Non compliant Location and fi...
  • Page 63: Starting-Up

    Ground source heat pump atlantic geolia 13 - 17 7.1.2 Starting-up • Switching On (see chapiter "Commissioning", page 25). Non compliant DISENGAGE the compressor thermal relay. Turn ON the start/stop switch => Initialisation for a few seconds. Set Time, Date and Time programs for HC1, (HC2), if diff erent than default values (settings 500 – 576).
  • Page 64: Settings Sheet

    Ground source heat pump atlantic geolia 13 - 17 Settings sheet Setting Description Set to. Menus Setting Description Set to. Menus Boiler back-up (si boiler connection kit) Preliminary settings 3700 OT.switch-on authoris. Addit. gen. language Operator section 3705 swith-off delay Addit.
  • Page 65: Erp Performance Values

    Ground source heat pump atlantic geolia 13 - 17 8 ErP performance values Energy performance data is available in the user manuals. 9 Instructions for the end user Explain to the end user how his installation operates, in  End of life of the device...
  • Page 66 Ground source heat pump atlantic geolia 13 - 17  - 66 - Installation and operating manual "1641 - EN"...
  • Page 67 Ground source heat pump atlantic geolia 13 - 17  Installation and operating manual "1641 - EN" - 67 -...
  • Page 68 Determination of acoustic power level. Keymark Certifi cation : 012-C700082 - ATLANTIC GEOLIA 13 012-C700083 - ATLANTIC GEOLIA 17 This appliance is marked with this symbol. This means that electrical and electronic products shall not be mixed with general household waste.

This manual is also suitable for:

Geolia 17522973522974

Table of Contents