Atlantic Alfea hybrid duo gas Series Installation And Commissioning Instructions

Atlantic Alfea hybrid duo gas Series Installation And Commissioning Instructions

Air/water heat pump with integrated gas burner, split, 2 services outdoor/hydraulic unit
Table of Contents

Advertisement

alféa hybrid duo gas
Air/water heat pump
with integrated gas burner,
split, 2 services
Outdoor unit
WOYG112LHT
WOYG112LCTA
WOYG140LCTA
WOYK112LCTA
WOYK140LCTA
WOYK160LCTA
Hydraulic unit
024200
Document n° 1485-20 ~ 04/01/2018
FR
EN
IT
DE
ES
PT
Installation and
commissioning
instructions
for professionals
to be kept by the user
for future reference
atlantic-comfort.com
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Alfea hybrid duo gas Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Atlantic Alfea hybrid duo gas Series

  • Page 1 Document n° 1485-20 ~ 04/01/2018 Air/water heat pump with integrated gas burner, split, 2 services Outdoor unit Hydraulic unit WOYG112LHT 024200 WOYG112LCTA WOYG140LCTA WOYK112LCTA WOYK140LCTA WOYK160LCTA Installation and commissioning instructions for professionals to be kept by the user for future reference atlantic-comfort.com...
  • Page 2: Table Of Contents

    Heat pump alféa hybrid duo gas Contents Presentation of the equipment . . . . . . . . . . . . . . . . . . . . . . . . . 5 Packaging General characteristics Optional equipment...
  • Page 3 Heat pump alféa hybrid duo gas Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 Checks before commissioning Starting the gas generator to check the combustion 48 Heating circulation pump speed settings...
  • Page 4 Heat pump alféa hybrid duo gas The following are required for the installation of this appliance: " qualified personnel, certified as capable of handling refrigerating fluids (according to environmental legislation ) . " a heating engineer . Certificate of conformity The use of a gas boiler requires a Certificate of Conformity signed by local authorities.
  • Page 5: Presentation Of The Equipment

    Heat pump alféa hybrid duo gas 1 Presentation of the equipment 1 .1 Packaging • 1 box: Choice of connection pipe. • 1 box: Outdoor unit. Concentric • 1 box: Hydraulic module with gas generator ... horizontal turbo pipe (073 224). and outdoor temperature sensor.
  • Page 6: General Characteristics

    Heat pump alféa hybrid duo gas 1 .5 General characteristics 11 three 14 three 16 three Model denomination alféa hybrid duo gas Gas category 2Esi3P CH - CZ - ES - IT - LT - PT - SK 2H3P DK - EE - FI - IT - SE LU - DE NOx class Nominal heating performances (T°...
  • Page 7 Heat pump alféa hybrid duo gas 11 three 14 three 16 three Model denomination alféa hybrid duo gas Domestic hot water tank Capacity of domestic hot water tank litre Max DHW circuit usage pressure (PMS) MPa (bar) 0.7 (7) Specific DHW flow rate at DT 30°K (D) l/mn Max temperature °C...
  • Page 8 Heat pump alféa hybrid duo gas " Outdoor unit, hybrid duo gas 11 single phase model, hybrid duo gas 14+ single phase model 4 holes Flow opening Orifice d’écoulement (Ø 20) 4 trous Ø 12 Bottom view Vue de dessous 1290 3/8”...
  • Page 9 Heat pump alféa hybrid duo gas " Hydraulic module Chimney connection Ø 80/125 49,3 Gas Ø 20x27 M Heating return Ø 26x34 M Heating flow Ø 26x34 M 1828 1800 1729 DHW Ø 20x27 M Cold water Ø 20x27 M 1229 271,5 Side view...
  • Page 10 Heat pump alféa hybrid duo gas Outdoor sensor QAC34 Variable pressure Ω 1 mbar = 10 mmCE = 100 Pa 43907 1 kΩ, 25 °C 10000 2490 1000 °C m /h Heat pump return sensor Heat pump flow sensor Constante pressure 32500 1 mbar = 10 mmCE = 100 Pa 30000...
  • Page 11: Description

    Heat pump alféa hybrid duo gas 1 .6 Description " hybrid duo gas 11 & 14+ single phase " hybrid duo gas 11, 14 & 16 3-phase Legend 1 - High performance impeller and low noise level. 2 - Electrical motor with variable "inverter" operation. 3 - "Inverter"...
  • Page 12 Heat pump alféa hybrid duo gas Legend: 15 - Pressure flap 16 - Disconnectable no return valve 1 - Chimney adaptor. 8 - Drainage tap 17 - Inspection trap a - Heating body 2 - Control panel: 18 - Titanium anode (ACI). b - Hot water exchanger Regulator / User interface, 19 - Adjustable feet...
  • Page 13: Operating Principle

    Heat pump alféa hybrid duo gas Legend: 1 - Regulator / User interface. figure 8 - 2 - On / off switch. Control panel 3 - ACI light 4 - Pressure gauge. 5 - Safety light. 1 .7 Operating principle The ambient sensor (optional) provides a corrective action to the water logic.
  • Page 14 Heat pump alféa hybrid duo gas • Regulation functions • Operating principle of the domestic hot water (DHW) - The initial temperature of the heating circuit is controlled by water logic. DHW production takes priority over heating. - In function of an initial heating temperature, the power Two domestic hot water (DHW) temperatures may of the outdoor unit is modulated via the "inverter"...
  • Page 15: Installation

    Heat pump alféa hybrid duo gas 2 Installation 2 .1 Installation and maintenance rules 2 .2 Unpacking and reserves The appliance must be installed and the maintained 2 .2 .1 Reception by an approved professional in accordance with the When the courier is present, carefully check the general prevailing regulations and code of practice, in particular: appearance of the appliances, check that the outdoor - The legislation on the handling of refrigerants.
  • Page 16: Accessories Supplied

    Heat pump alféa hybrid duo gas 2 .3 Installation of refrigerant connections 2 .2 .4 Accessories supplied Manipulate the pipes and made their " crossing (slab or wall) with protective caps in place or after brazing . " Keep the protective caps or ends soldered to the commissioning of the appliance .
  • Page 17: Installation Of The Outdoor Unit

    Heat pump alféa hybrid duo gas 2 .4 Installation of the outdoor unit 2 .4 .1 Installation precautions • The outdoor unit is able to withstand bad weather but The outdoor unit must be installed outdoor (outdoors). If a shelter is required, it must have avoid installing in a position where it is likely to be exposed to significant dirt or flowing water (under a broad openings on the 4 walls and observe the...
  • Page 18: Outdoor Unit Positioning

    Heat pump alféa hybrid duo gas • Keep the outdoor unit away from heat sources and inflammable products. • Make sure the appliance not disturb the surrounding area or users (noise level, draught generated, low temperature of the air being blown out, with the risk of freezing plants in its path).
  • Page 19: Installing The Hydraulic Unit

    Heat pump alféa hybrid duo gas 2 .5 Installing the hydraulic unit 2 .5 .1 Installation precautions • Choose the location of the appliance after discussion 300 mm with the client. • The room in which the appliance operates must comply with the prevailing regulations.
  • Page 20: Chimney Evacuation Pipe, B23, B23P

    Heat pump alféa hybrid duo gas 2 .6 Chimney evacuation pipe, B23, B23P The evacuation pipe must comply with the regulations in force The evacuation pipe must be dimensioned (according to standard NF EN 13384-1). The pipe must only be connected to a single appliance. The pipe must be waterproof.
  • Page 21: Concentric Horizontal Room-Sealed Pipe (C13 Type)

    Heat pump alféa hybrid duo gas 2 .8 Room-sealed connection pipe C13, C33, C53 B23 type chimney connection The connection pipe must be removable. By design, the boiler's smoke temperature cannot exceed 120 °C, therefore, there is no need to add an 16 and 24 evacuation pipe protection thermostat.
  • Page 22 Heat pump alféa hybrid duo gas C13 type pipe connection 90° 90° 90° 90° Mini 1899 mm 16 et 24 kW 1577 mm 28 et 34 kW 1698 mm ¤ 90° elbow = 1 m of straight pipe. ¤ 45° elbow = 0.5 m of straight pipe. Existing evacuation pipe.
  • Page 23: Concentric Vertical Pipe (C33 Type)

    Heat pump alféa hybrid duo gas 2 .8 .2 Concentric vertical pipe (C33 type) C53 type pipe connection Regulations The roof terminal must be placed at least 0.40 m away from any opening windows and 0.60 m away from any ventilation air intake openings.
  • Page 24 Heat pump alféa hybrid duo gas Opening Air inlet Dormer Below eaves or balconies 2 max mini 0,4 0,2 Gable with opening Blind gable Anti-snow Internal angle 0.15 0,15 0.85 0,85 mini 2 min 2 mini 2 min 2 mini 0.3 min 0,3 mini mini...
  • Page 25: Refrigerant Gas Connection And Filling The Installation With Gas

    Heat pump alféa hybrid duo gas 3 Refrigerant gas connection and filling the installation with gas " This appliance uses refrigerant R410A . material. Lastly, take care to use pipe insulators whose thermal conductivity is 0.045 W/mK or less Comply with the legislation for handling refrigerants. when the temperature is 20°C.
  • Page 26: Check And Connecting

    Heat pump alféa hybrid duo gas 3 .3 Check and connecting " The refrigerant circuit is very sensitive to dust and humidity: check that the area "Gas" around the connection is clean and dry before connection removing the plugs protecting the refrigerant Nitrogen connectors .
  • Page 27 Heat pump alféa hybrid duo gas Heat pump model alféa hybrid gas single phase / three phase liquid 5/8" 3/8" Raccords unité extérieure Diameter (D1) 5/8" (D2) 3/8" Minimum length (L) Liaisons frigorifiques 15 * / 20 ** Maximum length (L) Difference in height (D) 15 * / 20 ** Hydraulic module connectors...
  • Page 28: Filling The Installation With Gas

    Heat pump alféa hybrid duo gas 3 .4 Filling the installation with gas " This operation is reserved for installers familiar with the legislation for handling refrigerants. " Creating a vacuum with a vacuum pump is essential (see ANNEX 1). "...
  • Page 29: Seal Test

    Heat pump alféa hybrid duo gas 3 .4 .1 Seal test 3 .4 .2 Creating a vacuum - Remove the protective plugs (B) from the charging hole (Schrader) in the "Gas" valve (large diameter). The 3 empty method (ANNEX 2) is highly - Connect the high pressure hose to the Manifold recommended for any installation especially when - Connect the bottle of nitrogen to the Manifold...
  • Page 30: Filling The Installation With Gas

    Heat pump alféa hybrid duo gas 3 .4 .3 Filling the installation with gas 3 .4 .5 Additional charge 50 g of R410A per additional meter If an additional charge is requires, add the additional charge before filling the hydraulic unit Length of 15 m 20 m max.
  • Page 31 Heat pump alféa hybrid duo gas 3 .4 .6 Pump down operation (Refrigerant collecting operation) outdoor unit " Ensure that the general electrical power supply has been cut off before starting any repair work. stored energy: after disconnecting power " supplies wait 1 minute before accessing the internal parts of the equipment .
  • Page 32: Hydraulic Connecting And Gas Connecting

    Heat pump alféa hybrid duo gas 4 Hydraulic connecting and gas connecting " General The connection must comply with good trade practice according to local building regulations. Reminder: Seal everything when fitting in accordance with prevailing trade practice for plumbing work: - Use suitable seals (fibre seals, o-rings).
  • Page 33: Connecting To The Heating Circuit

    Heat pump alféa hybrid duo gas 4 .1 Connecting to the Heating circuit 4 .1 .2 Connecting The heating circulating pump is built into the hydraulic unit. 4 .1 .1 Rinsing out the installation Connect the central heating pipes to the appliance, Before connecting the hydraulic unit to the installation, complying with the direction of circulation.
  • Page 34: Overall Hydraulic Layout

    Heat pump alféa hybrid duo gas 4 .3 .1 Overall hydraulic layout • Configuration 10 : 1 heating circuit (radiators) °C • Configuration 10 : 1 heating circuit (heating floor system) kit PCBT /2 circuits °C - 34 - Installation and commissioning instructions "1485 - EN"...
  • Page 35 Heat pump alféa hybrid duo gas • Configuration 10 : 2 heating circuits (radiators + heating floor system) kit PCBT /2 circuits °C Caption : SA1 - Room sensor mixing circuit "CC1" (optional) SA2 - Room sensor direct circuit "CC2" (optional) BS - Domestic hot water tank SD - Flow sensor CAR - Non-return valve...
  • Page 36: Filling And Draining The Installation

    Heat pump alféa hybrid duo gas 4 .4 Filling and draining the installation - Check the attachment of the pipes, that the connectors are tight and that the hydraulic module is stable. - Check the direction of circulation of the water and that all of the valves are open.
  • Page 37: Gas Change

    Heat pump alféa hybrid duo gas 4 .5 Gas change " WARNING The gas generator is preset in the factory to Gas valve outlet G31 propane gas, domestic supply pressure: connector 37 mbar . • For use with G25 natural gas, domestic supply pressure: 25 mbar (Groninguen gas type), it is compulsory to remove the diaphragm on the gas valve outlet.
  • Page 38: Electrical Connections

    Heat pump alféa hybrid duo gas 5 Electrical connections Before carrying out any work, ensure that the general • Connection to the spring terminal blocks: electrical power supply is switched off. - The use of ring terminal or the tip is prohibited. - Always select a rigid wire that complies with the 5 .1 General...
  • Page 39: Overall View Of The Electrical Connections

    Heat pump alféa hybrid duo gas 5 .1 .3 Overall view of the electrical connections The electrical diagram of the hydraulic module is detailed in figure 62, page 72 Wireless room control unit T78 (option) Outdoor sensor: cable 2x0.5 mm² Wireless room thermostat T58 (option) Room control unit T75 (option): cable 3x0.5 mm²...
  • Page 40: Electrical Connections On Outdoor Unit Side (Single Phase Model)

    Heat pump alféa hybrid duo gas 5 .1 .5 Electrical connections on outdoor unit side (single phase model) Access to the connector terminals - Remove the front panel. Remove the screws and the - Make the connections according to the diagram front panel (figure 37).
  • Page 41: Electrical Connections On Outdoor Unit Side (Three Phase Model)

    Heat pump alféa hybrid duo gas 5 .1 .6 Electrical connections on outdoor unit side (three phase model) Access to the connector terminals - Remove the front panel. Remove the screws and the cover of the front panel. - Make the connections according to the diagram (figure 40).
  • Page 42: Electrical Connections On

    Heat pump alféa hybrid duo gas 5 .1 .7 Electrical connections on the hydraulic module side Access to the connector terminals Do not fit the sensor wires and the power supply wires in parallel in order to avoid interferences due to the - Remove the front panel.
  • Page 43 Heat pump alféa hybrid duo gas • Inter-connection between the outdoor unit and the hydraulic module: Respect the correspondence between the terminal blocks An incorrect connection can cause the destruction of one of the units. references of the hydraulic module and those of the outdoor unit when connecting the inter-connection cables.
  • Page 44: Outdoor Sensor

    Heat pump alféa hybrid duo gas 5 .3 Room thermostat • Second heating circuit and/or Room control unit - Refer to the instructions supplied with the 2 circuit hydraulic kit. The ambient thermostat (the central ambient unit) is • Load shedding or EJP (Delete peak rate day) optional The purpose of load shedding is to reduce the electrical Consult the assembly instructions on the packaging.
  • Page 45 Heat pump alféa hybrid duo gas Outdoor sensor Load shedding or EJP function Wireless room Wireless room (Peak Day Erasure) thermostat control unit T58** T78** Tariffs, day/night, peak/off peak (not concerned) External fault Outdoor contact device* (faults, load shedder, B2 M B1 3 2 1 energy meter) Room Room thermostat...
  • Page 46: Commissioning

    Heat pump alféa hybrid duo gas 6 Commissioning 6 .1 Checks before commissioning - Make sure that the installation has been rinsed. - At the first commissioning, pour a glass of water in the siphon. 6 .1 .1 Heating circulation pump speed settings 1 mbar = 10 mmCE = 100 Pa Variable pressure The circulator varies the manometric height...
  • Page 47: Gas Circuit

    Heat pump alféa hybrid duo gas LED Off: The pump does not work, no electrical power. Green LED on: The pump works normally. Green LED blink: Venting operating mode (10 minutes). Green/Red LED blink: Operating error with automatic reboot. Red LED blink: Operating error figure 49 - Operation signals the HP circulator 6 .1 .3 Gas circuit:...
  • Page 48: Starting The Gas Generator To Check The Combustion

    Heat pump alféa hybrid duo gas 6 .3 Starting the gas generator to check the combustion To carry out the combustion checks (during a gas change or during maintenance), the gas generator can be started independently of the heat pump (figure 51) "...
  • Page 49: Setting The Combustion Parameters During A Gas Check

    Heat pump alféa hybrid duo gas 6 .4 Setting the combustion parameters during a gas check To carry out the combustion checks (during a gas change or during maintenance), the gas generator can be started independently of the heat pump (figure 51) "...
  • Page 50: Configuring Room Thermostat (T55 Or T58)

    Heat pump alféa hybrid duo gas 6 .5 Configuring room thermostat (T55 or T58) To configure the ambient sensor and associate it to the 2: Save with confirmation; a correction of the value with the knob is only adopted after pressing the operation adequate heating zone: button.
  • Page 51 Heat pump alféa hybrid duo gas  Installation and commissioning instructions "1485 - EN" - 51 -...
  • Page 52: Regulation

    Heat pump alféa hybrid duo gas 7 Regulation 7 .1 User interface, Room control unit (option) and Room thermostat (option) User interface Auto Auto °C Room control unit T75 / T78 Room thermostat T55 / T58 figure 54 - - 52 - Installation and commissioning instructions "1485 - EN"...
  • Page 53 Heat pump alféa hybrid duo gas Item Functions - Definitions of the functions - On: Production of DHW in function of the timer programme. Selecting the DHW operation - Off: Production of the DHW stopped with antifreeze function of the domestic water active.
  • Page 54: Description Of The Display

    Heat pump alféa hybrid duo gas 7 .2 Description of the display Symbols Definitions - Compressor operation. - Burner operation authorisation. - Fault message (lists page 73, page 74) Xxxxxxxxxxxxxxxxxxxxxxxxxxx - Maintenance, special operation Xxxxxxxxxxxxxxxxxxxxxxxxxxx Xxxxxxxxxxxxxxxxxxxxxxxxxxx - Information level activated INFO (list page 78)
  • Page 55 Heat pump alféa hybrid duo gas Parameter 3700 (Release under ext. T°). Heat pump + gas generator operation 4 3,75 3,5 3,25 2,75 2,25 Traditional 1,75 radiator 1,25 Low temperature radiator 0,75 Underfloor heating (only with 2 circuit kit 0,25 option) Outdoor temperature °C figure 56 - Slope of the heating curve (line 720)
  • Page 56: Regulation Parameters

    Heat pump alféa hybrid duo gas 7 .4 Regulation parameters 7 .4 .2 Setting the parameters - Selecting the desired level. 7 .4 .1 General - Scroll the list of menus. Only the parameters accessible at the levels: - Selecting the desired menu. U - end user.
  • Page 57 Heat pump alféa hybrid duo gas Line Function Setting Setting range or display Basic setting increment User interface Language English, Français, Italiano, English Nederlands... Info Temporary, Permanent Temporary Operation locking On, Off Programming locking On, Off Direct setting Saving... automatic with confirmation ...with confirmation...
  • Page 58 Heat pump alféa hybrid duo gas Line Function Setting Setting range or display Basic setting increment Timer programme 4/DHW The DHW timer programme follows the heating timer programme, one hour ahead. To programme the DHW separately, you must first change parameter 1620 to "Timer programme 4/DHW". Preselection (day / week) Mon-Sun, Mon-Fri, Sat-Sun, Mon-Sun...
  • Page 59 Heat pump alféa hybrid duo gas Line Function Setting Setting range or display Basic setting increment Flow temp setpoint max Flow temp setpoint min... 70 °C 1 °C 55 °C Underfloor heating (compulsory with 2 circuit kit) = 50 °C / Radiators = 65 °C. Important note: The maximum limit is not a safety function as that required for under-floor heating.
  • Page 60 Heat pump alféa hybrid duo gas Line Function Setting Setting range or display Basic setting increment Heating adjustment, Circuit 2 Basic programme for a simple, 1 radiator circuit installation 1010 Comfort ambient temperature setpoint from reduced setpoint… 0.5 °C 20 °C to comfort setpoint max 1012 Reduced ambient temperature setpoint...
  • Page 61 Heat pump alféa hybrid duo gas Line Function Setting Setting range or display Basic setting increment DHW setting (domestic hot water) 1610 Comfort setting Reduced value (line 1612)… 55 °C 65 °C 1612 Reduced setting 8 °C... 40 °C Comfort value (line 1610) 1620 Release of DHW load 24h / day...
  • Page 62 Heat pump alféa hybrid duo gas Line Function Setting Setting range or display Basic setting increment Additional generator (Boiler connection) 3692 With DHW charging Locked, Substitute, Substitute Complement, Instantly - DHW Instantly : When DHW request, the HP and the boiler are put into operation. The HP will stop when the primary return temperature is over 55 °C.
  • Page 63 Heat pump alféa hybrid duo gas Line Function Setting Setting range or display Basic setting increment 5950 Function input H1 (Connector X86, terminals B1 & M) None 0: None, 1: Op'mode change zones+DHW, 2: Optg mode changeover DHW, 3: Op'mode changeover zones, 4: Op'mode changeover zone 1, 5: Op'mode changeover zone 2, 6: Op'mode changeover zone 3, 8: Error/alarm message, 9: Consumer request VK1, 10: Consumer request VK2, 11: Release swi pool source heat, 13: Release swi pool solar, 14: Operating level DHW, 15: Operating level HC1, 16: Operating level HC2,...
  • Page 64 Heat pump alféa hybrid duo gas Line Function Setting Setting range or display Basic setting increment 6375 Relay output QX35 Swimming pool pump Q19 0: None, 2: Process reversing valve Y22, 3: Hot-gas temperature setpoint K31, 4: Electric immersion heater 1 flow K25, 5: Electric immersion heater 2 flow K26, 6: Diverting valve cooling source Y28, 7: Primary pump Q14, 8: Cascade pump Q25, 9: Heat generation lock Y4, 10: Electric immersion heater DHW K6, 11: Circulating pump Q4, 12: Storage transfer pump Q11, 13: DHW intermediate circuit pump Q33, 14: DHW stirring pump Q35, 15: Collector pump Q5, 16: Collector pump 2 Q16,...
  • Page 65 Heat pump alféa hybrid duo gas Line Function Setting Setting range or display Basic setting increment Error 6711 Heat pump reset No, Yes 6800 History 1 Date, Time, Error code 6802 History 2 Date, Time, Error code 6804 History 3 Date, Time, Error code 6806 History 4...
  • Page 66 Heat pump alféa hybrid duo gas Line Function Setting Setting range or display Basic setting increment 7807 Sensor temperature BX4 (common start T°) -28... 350 °C 7830 Sensor temperature BX21 module 1 -28... 350 °C 7831 Sensor temperature BX22 module 1 -28...
  • Page 67 Heat pump alféa hybrid duo gas Line Function Setting Setting range or display Basic setting increment Diagnostics consumers 8700 Outside temperature -50... 50 °C 8701 Minimum outside temperature -50... 50 °C Reset ? (no, yes) 8702 Maximum outside temperature -50... 50 °C Reset ? (no, yes) 8703 Attenuated outside temperature...
  • Page 68 Heat pump alféa hybrid duo gas Line Function Setting Setting range or display Basic setting increment 8957 Common flow setpoint, refrigeration 0... 140 °C 9010 Measurement room temp 1 9011 Measurement room temp 2 9031 Relay output QX1 Off, On 9032 Relay output QX2 Off, On...
  • Page 69 Heat pump alféa hybrid duo gas  Installation and commissioning instructions "1485 - EN" - 69 -...
  • Page 70: Electrical Wiring Diagrams

    Heat pump alféa hybrid duo gas 8 Electrical wiring diagrams Pressure Printed Circuit Board Option(connector) sensor (Disply) Refer to the technical manual Thermistor (compressor) Thermistor (outdoor) Thermistor (pipe) Thermistor (discharge) Expansion Fuse valve coil Thermistor (heat sink) F4 T 5A - 250 V Thermistor (pipemid) Printed Circuit Board...
  • Page 71 Heat pump alféa hybrid duo gas Expansion valve coil (Inj) Solenoid coil (Inj) Thermistor Inverter PCB assy Inj expansion valve Thermistor heat exchanger mid Thermistor heatsink PFC Thermistor discharge pipe Thermistor heat exchanger out Compressor Thermistor outdoor temp. Thermistor Capacitor (Heatsink inv.) PCB assy Thermistor...
  • Page 72 Heat pump alféa hybrid duo gas Return Pressure Capteur Reset Retour Smoke Start sensor de pression Fumées Départ Ventilateur Carte Gas regulation régulation board Condensation Sonde sensor condensation Gas valve CN18 Vanne X18a CN16 Boitier CN30 Ignition unit allumage Transformateur Ignition allumage transformer...
  • Page 73: Fault Diagnostic

    Heat pump alféa hybrid duo gas 9 Fault diagnostic Depending on whether the fault is on the outdoor unit or the hydraulic module, the fault may be advised by the digital display or the LED on the interface boards. " Before carrying out any work, ensure that the general electrical power supply is switched off. "...
  • Page 74 Heat pump alféa hybrid duo gas Hydraulic module: Boiler regulator faults (LMS) visible on the digital display. Error codes Type of anomaly Probable causes Action Error on the boiler Shutdown of the Boiler sensor in - Check the sensor cabling sensor appliance short-circuit...
  • Page 75 Heat pump alféa hybrid duo gas Hydraulic module: Flashing LED visible on the 3 in 1 interface board. LED display Outdoor unit Error contents Error number LED 2 (green) LED 1 (red) 1 Flash 1 Flash Communication error between Hydraulic unit and Outdoor unit. 2 Flashs 3 Flashs Connection forbidden (series error).
  • Page 76: Faults Displayed On The Single Phase Outdoor Unit

    Heat pump alféa hybrid duo gas 9 .2 Faults displayed on the single phase outdoor unit To access the electronic board, you must remove the front (right-hand) facing from the outdoor unit. Faults are coded by diode flashes. When an error occurs: - The diode "ERROR"...
  • Page 77: Faults Displayed On The 3-Phase Outdoor Unit

    Heat pump alféa hybrid duo gas 9 .3 Faults displayed on the 3-phase outdoor unit Diodes and switches To access the electronic board, you must remove the front (right-hand) facing from the outdoor unit. Faults are coded by diode flashes. When an error occurs: - The diode "ERROR"...
  • Page 78: Display Information

    Heat pump alféa hybrid duo gas 9 .4 Display information The Info button calls up various information. - Miscellaneous information (see below). Depending on the appliance type, the configuration and Designation Line the state of operation, certain information lines may not Floor drying current setpoint.
  • Page 79: Servicing Of The Installation

    Heat pump alféa hybrid duo gas 10 Servicing of the installation Before carrying out any work, ensure that the general electrical power supply is switched off. The boiler must be serviced regularly to maintain high its output. Depending on the operating conditions, the servicing operation is to be carried out once or twice a year.
  • Page 80: Servicing The Evacuation Pipe

    Heat pump alféa hybrid duo gas 10 .3 Servicing the evacuation pipe The suction pipe (or the chimney) must be checked and cleaned regularly by a specialist (once a year). - Check that the suction pipe is not obstructed. - Check that the condensate evacuation is not blocked. Remove the siphon and rinse it in clean water.
  • Page 81: Maintenance

    Heat pump alféa hybrid duo gas 11 Maintenance 11 .1 Draining the hydraulic module - Remove the front panel of the heat pump. Flap closed (Normal operating - Set the directional valve to intermediate position. position) - Deactivate the non-return valve (item 4, figure 69).
  • Page 82: Start-Up Procedure

    Heat pump alféa hybrid duo gas 12 Start-up procedure Before switching on the hydraulic module: • Check the electrical cabling. • Check that the refrigeration circuit is filled with gas. • Check the hydraulic circuit's pressure (1 to 2 bars), check that the heat pump is drained, along with the rest of the installation.
  • Page 83: Start-Up

    Heat pump alféa hybrid duo gas 12 .1 .2 Start-up • Starting (see § "6.2 Commissioning the heat pump", page 47). Non conforming Push in the installation's general circuit breaker (outdoor unit power supply) 2 hours before the tests => Compressor preheating. Push in the on/off switch =>...
  • Page 84: Configuration File

    Heat pump alféa hybrid duo gas 12 .2 Configuration file Parameter Designation Setting Menus Parameter Designation Setting Menus Boiler reading Prior settings 3700 On author. ext. T° addit. gener. language inter. Use Miscellaneous hour / minuts time and date 6420 H33 input function configuration day / month...
  • Page 85: Technical Commissioning Instructions

    Heat pump alféa hybrid duo gas 12 .3 Technical commissioning instructions Site Installer Serial No. Serial No. Outdoor unit Hydraulic module Model Model Type of refrigerating fluid Refrigerating fluid load Checks Voltages and intensities in operation on the outdoor unit Location distances respected L/N or L1/N Condensate evacuation OK...
  • Page 86: Erp Performance Values

    - Eco-design directive sets effiency thresholds and prohibits the sale of any product with efficiency lower than the set thresholds. - According to labelling directive, energetic efficiency shall be displayed to encourage end-users to purchase energy-efficient products. 13 .2 ErP specifications Trade name / Models : atlantic / alfea ... hybrid duo hybrid duo hybrid duo...
  • Page 87 Heat pump alféa hybrid duo gas Trade name / Models : atlantic / alfea ... hybrid duo hybrid duo hybrid duo hybrid duo hybrid duo 11 mono 14+ mono 11 tri 14+ tri 16 tri Reference 522524 / 522525 /...
  • Page 88: Package Fiche

    Heat pump alféa hybrid duo gas 13 .3 Package fiche hybrid duo gaz hybrid duo gaz hybrid duo gaz hybrid duo gaz Models alfea . . . hybrid duo gaz 11 tri 11 tri 14 tri 16 Reference 522524 / 522197 522525 / 522198 522473 / 522184 522474 / 522185...
  • Page 89: Values To Be Given To The User

    Heat pump alféa hybrid duo gas 14 Values to be given to the user Explain to the user the operation of the installation " End of life of the device (heating and hot water temperature settings), especially Disassembly and recycling shall be handled by a the ambient sensor functions and the programmes that qualified body.
  • Page 90 Heat pump alféa hybrid duo gas  - 90 - Installation and commissioning instructions "1485 - EN"...
  • Page 91 Heat pump alféa hybrid duo gas  Installation and commissioning instructions "1485 - EN" - 91 -...
  • Page 92 This appliance must be treated at a specialized treatment facility for re-use, recycling and other forms of recovery and shall not be disposed of in the municipal waste stream. Please contact the installer or local authority for more information. * subject to the national law of each member state Date of commissioning: atlantic-comfort.com www.atlantic.fr Société Industrielle de Chauffage SATC - BP 64 - 59660 MERVILLE - FRANCE...

Table of Contents