Summary of Contents for Atlantic Geolia 5

  • Page 1 Document n° 1639-9 ~ 30/08/2019 Ground source heat pump water/water and brine/water atlantic geolia 5 atlantic geolia 7 atlantic geolia 10 atlantic geolia 13 atlantic geolia 17 Operation manual intended for professionals and end users. To be saved for future consultation atlantic-comfort.com...
  • Page 2: Table Of Contents

    Ground source heat pump atlantic geolia Contents Instructions to be read before using the equipment Safety instructions Brine circuit End of life of the device Heat pump Precautions and warnings regarding your installation 3 Heating emitters Domestic hot water (DHW)
  • Page 3: End Of Life Of The Device

    Ground source heat pump atlantic geolia " Do not open the outdoor unit or the hydraulic unit while they are operating " Switch off the power supply if there are any abnormal noises, smells or smoke coming from the appliance and contact your installer "...
  • Page 4: Heat Pump

    Ground source heat pump atlantic geolia 1 3 2 Heat pump 1 3 4 Domestic hot water (DHW) The heat pump contains the complete control system, This function is performed optionally with the use of a in charge of controlling the heating comfort level and the...
  • Page 5: Overall View Of The Installation

    Ground source heat pump atlantic geolia 2 Overall view of the installation Your heat pump has been configured by your installer. It is composed of the following main elements: - The brine circuit (surface or borehole) extracts energy from the ground...
  • Page 6: Operation Of The Installation

    Ground source heat pump atlantic geolia 3 Operation of the installation User interface figure 2 - User interface - 6 - Operation manual "1639 - EN"...
  • Page 7 Ground source heat pump atlantic geolia Functions - Definitions Selecting of the DHW operating mode If the installation is fitted with a DHW tank: (Domestic hot water) - On: Production of DHW according to the time program - Off: Preparing the domestic hot water for stopping with the anti-frost function...
  • Page 8: Description Of The Display

    Ground source heat pump atlantic geolia Description of the display Symbols Definitions - Heating mode active with reference to the heating circuit - Heating in comfort mode - Heating in reduced mode Xxxxxxxxxxxxxxxxxxxxxxxxxxx Xxxxxxxxxxxxxxxxxxxxxxxxxxx - Heating in "standby" mode (freeze protection)
  • Page 9 Ground source heat pump atlantic geolia  Operation manual "1639 - EN" - 9 -...
  • Page 10: Appliance Start Up

    Ground source heat pump atlantic geolia Appliance start up • The installation and 1 start up of the appliance must be done by a qualified installer. That person will also User interface give you instructions on starting and running the...
  • Page 11: Setting Time, Date And Language

    Ground source heat pump atlantic geolia 3 4 1 Setting Time, Date and Language Press to go to "End user" level Line No. Selection Settings - Time and date - User interface - Heating time program circuit 1 Language English...
  • Page 12: Selecting And Setting The Heating Operating Mode

    Ground source heat pump atlantic geolia 3 4 2 Selecting and setting the heating operating mode • Selecting the heating operating mode To select the heating operating mode, press several time on mode "Auto" : Automatic mode controls room temperature according to...
  • Page 13 Ground source heat pump atlantic geolia Heating periods programming example Heating period from Monday to Friday (Mon-Fri) A program can be performed for the period from Saturday to Sunday (Sat-Sun) Each day of the week can be programmed differently and independently.
  • Page 14: Selecting And Setting The Dhw Operating Mode (Option)

    Ground source heat pump atlantic geolia 3 4 3 Selecting and setting the DHW operating mode (option) • Change the DHW operating mode To change from "Active" mode to "Off" mode, press several times the DHW mode key DHW On :...
  • Page 15 Ground source heat pump atlantic geolia DHW heating periods programming example DHW heating period from Monday to Friday (Mon-Fri) A program can be performed for the period from Saturday to Sunday (Sat-Sun) Each day of the week can be programmed differently and independently.
  • Page 16: Holiday Periods

    Ground source heat pump atlantic geolia 3 4 4 Holiday periods It is possible to adjust holiday periods during which the heating is reduced mode or frost protection It is possible to set up to 8 periods DHW does not work during these periods Auto "...
  • Page 17: Swimming Pool Temperature Setting And Cooling (Option)

    Ground source heat pump atlantic geolia 3 4 5 Swimming pool temperature setting and cooling (option) • Set the swimming pool temperature (Swimming pool kit option) Press to go to "End user" level Line No. Selection Settings - Domestic Hot Water...
  • Page 18: Setting Parameters

    Ground source heat pump atlantic geolia Setting Parameters 3 5 1 General 3 5 2 Setting parameters Only the parameters accessible to levels: With the screen on basic display End user - Press are described in this document Once in "End user" level...
  • Page 19 Ground source heat pump atlantic geolia Line Function Setting range Setting range Basic or display or display setting Heating time programme, circuit 1 Pre-selection (Day / Week) Mon-Sun, Mon-Fri, Sat-Sun, Mon-Sun Monday, Tuesday, … phase On (start) 00:00 --:-- 10 min...
  • Page 20 Ground source heat pump atlantic geolia Line Function Setting range Setting range Basic or display or display setting Time programme 5 / Cooling If the installation is fitted with the cooling kit (Only with the cooling kit option). Pre-selection (Day / Week)
  • Page 21 Ground source heat pump atlantic geolia Line Function Setting range Setting range Basic or display or display setting Domestic hot water If the installation is fitted with the DHW kit. 1610 Nominal setpoint Reduced setpoint (line 1612)… 1 °C 55 °C 65 °C...
  • Page 22: Information Display

    Ground source heat pump atlantic geolia Information display Various data can be displayed by pressing the . Depending on the type of unit, configuration and operating state, some of the info lines listed below may not appear - Possible error messages: The display shows the symbol "...
  • Page 23: Maintenance

    Ground source heat pump atlantic geolia 4 Maintenance Brine circuit checks In order to insure your appliance operates correctly for many years, the maintenance operations described - Check glycol (Ph + Refracto) once a year below are required at the start of each heating season...
  • Page 24: Erp Performance Values

    Ground source heat pump atlantic geolia 5 ErP performance values ErP Definition "ErP" includes two directives that are part of the program for the reduction of green house gas emission : - Eco-design directive sets effiency thresholds and prohibits the sale of any product with efficiency lower than the set thresholds.
  • Page 25 Ground source heat pump atlantic geolia Trade name / Models : atlantic / alfea geolia 5 geolia 7 geolia 10 Reference 522452 522453 522454 Space heating application 35°C 55°C 35°C 55°C 35°C 55°C Water/water information Declared capacity for heating for part load at indoor temperature 20°C and outdoor temperature Tj Tj = -7°C...
  • Page 26: Package Fiche

    Ground source heat pump atlantic geolia Trade name / Models : atlantic geolia 5 geolia 7 geolia 10 Reference 522452 522453 522454 Space heating application 35°C 55°C 35°C 55°C 35°C 55°C Water/water and brine/water information Power consumption in modes other than active mode...
  • Page 27 Ground source heat pump atlantic geolia • Application 55 ° : < 30% ≥ 30% ≥ 34% ≥ 36% ≥ 75% ≥ 82% ≥ 90% ≥ 98% ≥ 125% ≥ 150% Models Atlantic Geolia 5 Atlantic Geolia 7 Atlantic Geolia 10...
  • Page 28: Erp Specifications 3-Phase

    Ground source heat pump atlantic geolia ErP specifications 3-Phase Trade name / Models : atlantic geolia 13 geolia 17 Reference 522455 522456 Space heating application 35°C 55°C 35°C 55°C Water/water and brine/water heat pump Equipped with a supplementary heater Water/water information...
  • Page 29 Ground source heat pump atlantic geolia Trade name / Models : atlantic geolia 13 geolia 17 Reference 522455 522456 Space heating application 35°C 55°C 35°C 55°C Declared coefficient of performance or primary energy ratio for part load at indoor temperature 20°C and outdoor temperature Tj Tj = -7°C...
  • Page 30: Fiche Package

    Ground source heat pump atlantic geolia 5 3 1 Fiche package Outdoor sensor included in the package 073951 (Wired room sensor T55 T55) Modulating room thermostat 075313 (Radio room sensor T58) references (outdoor sensor included Controller class 073954 (Wired room sensor T75)
  • Page 31 Ground source heat pump atlantic geolia • Application 55 ° : < 30% ≥ 30% ≥ 34% ≥ 36% ≥ 75% ≥ 82% ≥ 90% ≥ 98% ≥ 125% ≥ 150% Models Atlantic Geolia 13 Atlantic Geolia 17 Reference 522 455...
  • Page 32 Please contact the installer or local authority for more information * subject to the national law of each member state Date of installation : www. atlantic-comfort.com Société Industrielle de Chauffage SATC - BP 64 - 59660 MERVILLE - FRANCE Contact of your heating technician or your after-sales service.