5.2. Access the Built-In Web Interface

5.2.1. Required IP Address Settings

To be able to access the Bolt Serial built-in web interface you may need to adjust the IP settings, choose one of
the following methods.
The Bolt Serial default IP address is 192.168.0.99.
Option 1 - Set a Static IP Address on Your PC
On the PC accessing the Bolt Serial built-in web interface, set a static IP address within the same IP address range
as the Bolt Serial IP address.
Note that when you change to a static IP address on your PC, internet access is lost.
Option 2 - Change the IP Address on the Bolt Serial Ethernet port
Use the software application HMS IPconfig to find and change the IP address on the Bolt Serial Ethernet port, to
one within the same IP address range as the PC accessing the Bolt Serial built-in web interface.
To download the installation files, please visit
www.anybus.com/support
and enter the product article number to
search for the Bolt Serial support web page. You find the product article number on the product cover.
Result
Now you can enter the Bolt Serial IP address in your web browser and search to access the built-in web interface
login page.
See
Log In to the Built-In Web Interface (page
12).