Solmetric PVA-1500V2 Quick Reference Card
Hide thumbs Also See for PVA-1500V2:

Advertisement

Quick Reference Card
PVA-1500V2/V3/V4/T & SolSensor 300V2
For use with PVA PC software version 4.0 and later
WARNING - Risk of electrical shock. To be used only by qualified
personnel. Use Personal Protective Equipment. Isolate PV circuit to be
tested from inverter & other PV circuits. Use only PVA-1500 test leads.

I-V Measurement Unit specifications

Measurement ranges: 20 to 1500V DC, 0 to 30 A DC (high efficiency modules
limited to single strings)
Operating temperature: 0 to 45

Test Lead and Clip specifications

Measurement ranges: 1500V DC Max, 30 A DC Max
Operating conditions: Temperature 5 to 40C. Humidity – see User Guide.
Caution Use only the test leads & Dolphin clips provided with the PVA-1500.
Inspect before each use. If damaged, replace them before further use.
Caution Keep PV connectors, test leads, and equipment clean
Caution Keep the PV connector-saver jumpers attached to the I-V Unit's main
leads at all times. Replace them after each 100 connections.
Warning Do not touch white 'eye' of irradiance sensor. Cover when not in use.
Clean only with distilled water and clean, soft cloth, no soaps.
Battery Run Time: I-V Unit & SolSensor: 8hr continuous use. Charge nightly.
Network Connection: Select "pva1500_yyyyyy" from PC's Wi-Fi network list.
SolSensor
will automatically connect via I-V unit.
TM

I-V Unit LED

Off
Rapid flashing
Steady ON
Very slow
flashing
Slow flashing /
Steady ON
Five flashes,
pause, repeat
To turn off I-V Unit: In any state, press the pushbutton 3x
To reset I-V Unit or SolSensor: Hold pushbutton down 12 seconds & release
o
C (32 to 113
I-V Unit State
Off
Attempting to reconnect the
I-V Unit with the PC
Connected to PC, sweep
enabled
Paused (will turn off
automatically in 15 minutes
Battery charging / charged
Re-pairing with SolSensor.
o
F)
Pushbutton
Press once to turn on
Press 3x to turn off.
Press once to pause, or
3x to turn off.
Press once to enable
sweep, or 3x to turn off.
See User Guide to
initiate re-pairing
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PVA-1500V2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Solmetric PVA-1500V2

  • Page 1 ® Quick Reference Card PVA-1500V2/V3/V4/T & SolSensor 300V2 For use with PVA PC software version 4.0 and later WARNING - Risk of electrical shock. To be used only by qualified personnel. Use Personal Protective Equipment. Isolate PV circuit to be tested from inverter &...
  • Page 2 “Disabled” message: Click the status indicator for more information. Clear the underlying condition, (over-voltage, -current, -temp, low battery) and reset I-V Unit or charge the battery. Software updates: www.solmetric.com/downloads-pva.html Technical Support: Phone: 877-263-5026 Ext 2, support@solmetric.com Copyright 2022 Solmetric Corp. All rights reserved. Printed January 2022...

This manual is also suitable for:

Pva-1500v3Pva-1500v4Pva-1500tSolsensor 300v2Pva-1000sPva-600+

Table of Contents