Fill Consumables; Refill Of Internal Storage Container - Meiko M-iClean U Operating Instructions Manual

Glass, utensil and dishwasher
Table of Contents

Advertisement

8.4

Fill consumables

8.4.1

Refill of internal storage container

38 / 64
Warning
Risk of injury from contact with chemicals
Observe the safety data sheets and dosing recommendations of the chemical
manufacturers.
Use eye protection.
Wear protective gloves.
Do not mix different chemical products.
1. If required, activate the machine display by pressing the Service/WakeUp key.
The machine indicates the shortage of detergent and/or rinse aid on the display.
The internal storage containers must be topped up.
2. Press the illuminated blue button in the lower front panel.
3. Open front panel.
Dosing recommendation
4. Pour the appropriate chemical for dosing into the measuring cup provided.
Maximum filling quantity
Detergent
Rinse aid
5. Use the funnel to help pour the chemical carefully into the machine until the
storage container is full. Check the fill level via the fill level window (1).
– Blue: rinse aid
– Transparent: detergent
6. Rinse the funnel and measuring cup.
7. Close the lower front panel using the push button.
M-iClean US
M-iClean UM/UM+/UL
400 ml
80 ml
1000 ml
150 ml
9763258