Mtcdt-210 No Modem And No Accessory Cards - Multitech Conduit MTCDT Series Hardware Manual

Table of Contents

Advertisement

POWER DRAW
Radio Protocol
24.0 Volts
LTE
1
Max Power: The continuous current during maximum data rate with the radio transmitter at maximum power.
2
Peak Tx Current: The average peak current during LTE connection.
3
Total Inrush Charge: The total inrush charge at power on expressed in Millicoulombs (mC).
Note:
Multi-Tech Systems, Inc. recommends that you incorporate a 10% buffer into the power source when
determining product load.

MTCDT-210 No Modem and No Accessory Cards

Voltage
9.0 Volts
12.0 Volts
24.0 Volts
1
No Connections: Typical measure performed with the unit powered up only–no connections to the device.
2
Ethernet Connected Only: Typical power with Ethernet measured and the device attached to PC with Ethernet
cable only.
3
Maximum Current: Maximum current measured with Ethernet connected, SD Card, and USB Device actively
running read/write script, USB Debug and Host active running find/command.
4
Total Inrush Charge: The total inrush charge at power on expressed in Millicoulombs (mC).
Note:
Multi-Tech Systems, Inc. recommends that you incorporate a 10% buffer into the power source when
determining product load
20
Idle Cellular
Average Tx
Connection no
Current at Max
data (Amps)
Power Passing
Data (Amps)
0.096
0.227
No Connections
Ethernet
1
(Amps)
Connected only
(Amps)
0.151
0.168
0.130
0.139
0.080
0.086
Peak Tx Current
2
(Amps)
1
0.300
Maximum
Current (Amps)
2
0.265
0.204
0.114
Total Inrush
Total Inrush
3
Charge (mC)
Charge Duration
(mS)
2.75
7.43
Total Inrush
Total Inrush
3
4
Charge (mC)
Charge Duration
(mS)
2.37
1.05
3.4
8.24
2.8
22.7
Conduit
®
Hardware Guide

Advertisement

Table of Contents
loading

Table of Contents