RFSA-166M
Wireless switch unit
EN
Šestokanalna prekidačka jedinica za kontrolu ventilatora
RS
Characteristics /
Karakterisitke
• Thanks to the 6-channel design of the switching component it can control the heating / cool-
ing mode and with 3 speeds, , the RE6 output channel can be used to control appliances,
sockets or lights.
• The RFSA-166M wireless switching component can be combined with the RFTC-150/G.
• Up to 25 detectors RFWD-100 can be assigned to the switching component.
• The RFWD-100 can be assigned to the RFSA-166M using the PRG button.
• Output Channel RE6:
- Up to 25 channels can be controlled (1 channel represents one button on the controller).
- can be combined with detectors, controllers or system components of iNELS RF Control.
- Function: button, pulse relay and delayed start or return time functions with 2s-60min time
setting.
- Memory status is retained in the event of a power failure.
- The PRG6 programming button on the component also serves as manual control of the RE6
output.
• The package includes an internal antenna AN-I, in case of locating the element in a metal
switchboard, you can use the external antenna AN-E for better signal reception.
• Range up to 100 m (in open space), if the signal is insufficient, use the signal repeater RFRP-20
or protocol component RFIO
that support this feature.
2
• For components it is possible to set the repeater function via the RFAF/USB service device.
• Communication frequency with bidirectional protocol iNELS RF Control
Assembly /
Montaža
mounting into switchboard /
montaža u ormar
Radio frequency signal penetration through various construction materials /
Prenos radio frekvencijskih signala preko različitih građevinskih materijala
60 - 90 %
80 - 95 %
wooden structures
brick walls
with plaster boards
zid od
drvena konstuk-
cigle
cija sa gipsanim
pločama
Made in Czech Republic
2
(RFIO
20 - 60 %
0 - 10 %
reinforced
metal partitions
concrete
metalne pre-
grade
armirani beton
U-Energister, d.o.o.| Noveških interniraca 1V | 31000 Užice | Serbia | e-mail: office@elkoep.rs
U-Energister, d.o.o. | Norveških interniraca 1V | 31000 Užice | Republika Srbija | e-mail: office@elkoep.rs
Support: +381 63 479 880 |
EN
• Zahvaljujući 6- kanalnom dizajnu prekidačka jedinica kontroliše grejanje i hlađenje sa 3
nivoa brzine, RE6 izlazni kanal se može koristiti za kontrolu osvetljenja, utičnica, itd.
• RFSA-166M bežična prekidačka jedinica može se kombinovati sa RFTC-150/G.
• Prekidačkoj jedinici može se dodeliti do 25 detektora RFWD-100
• RFWD-100 može se dodeliti RFSA-166M pomoću PROG tastera.
• Izlazni kanal RE6:
- može se kontrolisati do 25 kanala, može se kombinovati sa detektorima, kontrolerima
ili komponentama iNELS RF kontrole sistema.- lze jej kombinovat s Detektory, Ovladači
nebo Systémovými prvky iNELS RF Control.
- funkcije: taster, impulsni relej i odloženo startno i povratno vreme za 2 s -60 min vremen-
sko podešavanje.
- mogućnost podešavanja statusa memorije u slučaju nestanka struje.
- Taster za programiranje PRG6 na jedinici takođe služi kao ručna kontrola RE6 izlaza.
• Paket uključuje unutrašnju antenu AN-I, u slučaju da se pretvarač nalazi u metalnoj razvod-
noj tabli, možete koristiti spoljnu antenu AN-E za bolji prijem signala.
Za elemente označene kao iNELS RF Control
putem RFAF / USB servisnog uređaja.
• Domet do 100 m (na otvorenom), ako je signal slab između kontrolera i jedinice, koristiti
ponavljač signala RFRP-20 ili komponentu protokola RFIO2 koja podržava ovaj sistem.
2
).
• Frekvencija komunikacije sa dvosmernim protokolom iNELS RF Control
Connection /
80- 90 %
common glass
staklo
Tehnička podrška +381 63 479 880
RS
www.elkoep.rs
(RFIO
), moguće je podesiti funkciju repetitora
2
2
Konekcija
Cool
Heat
N
L
02-12/2018 Rev.0
(RFIO
).
2
2
M
1 / 8

Advertisement

loading
Need help?

Need help?

Do you have a question about the iNELS RFSA-166M and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Elko iNELS RFSA-166M

  • Page 1 RFSA-166M Wireless switch unit Šestokanalna prekidačka jedinica za kontrolu ventilatora 02-12/2018 Rev.0 Characteristics / Karakterisitke • Thanks to the 6-channel design of the switching component it can control the heating / cool- • Zahvaljujući 6- kanalnom dizajnu prekidačka jedinica kontroliše grejanje i hlađenje sa 3 ing mode and with 3 speeds, , the RE6 output channel can be used to control appliances, nivoa brzine, RE6 izlazni kanal se može koristiti za kontrolu osvetljenja, utičnica, itd.
  • Page 2 RFSA-166M Wireless switch unit Šestokanalna prekidačka jedinica za kontrolu ventilatora 02-12/2018 Rev.0 Indication, manual control / Indikacije i ručna kontrola LED RE1 - 3 • LED Un - green - power supply indication. • LED Un - zelena - indikacija napona napajanja. Fan coil Function: Funkcija ventilatora: PROG button / RFSA-166M • LED RE1 - 3 - red - indication of fan speed. • LED RE1 - 3 - crvena - indikacija brzine ventilatora. taster PROG LED Un • LED RE4, RE5 - red - heating / cooling indication.
  • Page 3 RFSA-166M Wireless switch unit Šestokanalna prekidačka jedinica za kontrolu ventilatora 02-12/2018 Rev.0 RFSA-166M programming with RFWD-100 detector / Programiranje RFSA-166M sa RFVD-100 detektorom Press of programming but- Insert the battery into the Press of programming but- RFWD-100 ton on receiver RFSA-166M for ton on receiver RFSA-166M detector (see the detector 1second will activate receiver...
  • Page 4 RFSA-166M Wireless switch unit Šestokanalna prekidačka jedinica za kontrolu ventilatora 02-12/2018 Rev.0 Functions Switching component (RF functions and programming control) / Element za prebacivanje funkcija (funkcije i programiranje pomoću RF kontrolera) Function button / Funkcija taster Description of button / Opis funkcije taster The output contact will be closed by pressing the button and opened by releasing Izlazni kontakt zatvara se pritiskom na taster, otvara se otpuštanjem tastera.
  • Page 5 RFSA-166M Wireless switch unit Šestokanalna prekidačka jedinica za kontrolu ventilatora 02-12/2018 Rev.0 Function impulse relay / Funkcija impulsnog releja Description of impulse relay / Opis funkcije impulsnog releja The output contact will be switched to the opposite position by each press of Izlazni kontakt se prebacuje u suprotno stanje svaki put kada se pritisne tas- the button.
  • Page 6 RFSA-166M Wireless switch unit Šestokanalna prekidačka jedinica za kontrolu ventilatora 02-12/2018 Rev.0 Function delayed on / Funkcija odloženog uključivanja Description of delayed on / Opis funkcije odloženog uključivanja The output contact will be opened by pressing the button and closed after the set Izlazni kontakt se otvara / zatvara nakon pritiska na dugme nakon isteka pode- time interval has elapsed.
  • Page 7 RFSA-166M Wireless switch unit Šestokanalna prekidačka jedinica za kontrolu ventilatora 02-12/2018 Rev.0 Delete actuator / Brisanje elemenata Deleting one position of the transmitter / Brisanje jedne pozicije na kontro- Deleting the entire memory / Brisanje cele memorije leru By pressing the programming button PRG6 on the actuator for By pressing the programming button PRG6 on the actuator for 5 seconds, deletion of one transmitter activates.
  • Page 8: Technical Parameters

    RFSA-166M Wireless switch unit Šestokanalna prekidačka jedinica za kontrolu ventilatora 02-12/2018 Rev.0 Technical parameters / Tehnički parametri Supply voltage: Napon napajanja: 110-230 V AC / 50-60 Hz Apparent input: Prividna snaga ulaza: min. 2 VA / max. 5 VA Dissipated power: Maksimalna potrošnja: min.