4.2.1 Cleaning the equipment
In accordance with section 4.1.3, it is necessary to carry out a deep cleaning of the equipment. It must be carried out when the device
is cold, with a brush or dry cloth, and without applying water to metal parts in order to avoid rust.
For the cleaning of the smoke extractor, the vermiculite extractors must be removed to ensure that there is no obstruction or
damage as per the instructions in section 4.1.3. Vermiculite is a very fragile material, so handle with care.

4.2.2 Cleaning and replacement of the turbines.

Dirt (dust, lint, pets' hairs, etc.) may accumulate in the turbines and grilles and in proximity to same as a result of the absorption of the
ambient air of the room. To ensure the correct running of the equipment it is necessary to remove this dirt.
To replace the turbines in the GALAXY and TAURUS insertable devices, open the door and remove the grille corresponding to
the turbine in question. Remove the three screws indicated to extract the turbine together with the support bracket. Finally, remove
the two lower screws and the back of the support bracket to completely release the turbine.
Replacement of the turbines in the GALAXY/TAURUS insertable devices
To replace the turbines in the PANORAMIC insertable devices, remove the six screws from the grilles and extract it some 15 cm
outwards. Then release the cables from the winches (PANORAMIC 70) or screw unscrew the central cable cover (PANORAMIC 90)
and fully extract the grille-support of the turbines.
Replacement of the turbines in the PANORAMIC 70 (L) and PANORAMIC 90 (R)
4.2.3 Replacement of glass seal and door seal
The door of the device has two airtight seals to prevent residue such as ash from entering the room or any filtrations of air to the
interior of the combustion chamber. The first of these is located at the back of the door (cord) and the second between the glass
and the door itself. These seals must be replaced when signs of wear and tear are observed.
To replace the door seal cord, open the door and remove the old seal. Remove any remains of dirt, part of the old seal or adhesive.
Then apply the new seal using heat-resistant silicone.
To replace the seal between the glass (flat cord) and the door, extract the glass as indicated in section 4.2.4 and replaced it re-
moving the remains of the old seal and dirt. Apply the new seal to the door.

4.2.4 Replacement of glass

The glass must be replaced when it is found to be deteriorated. Remember that this is a special vitro ceramic glass resistant
to high temperatures (750 °C), therefore it is highly recommended to use original spare parts supplied by FERLUX Chimeneas y
Barbacoas.
To replace the glass, remove the screws from the lower and upper supports of the pane in the insertable GALAXY and TAURUS
devices, and the upper and side supports in the PANORAMIC insertable devices. Remember the seal should be replaced every time
the glass is changed. Apply the new seal and the glass.