10. Troubleshooting - DieHard 200.71522 Operator's Manual

Power inverter 140 converts 12v dc power to 110v ac household electrical power + usb (5v)
Table of Contents

Advertisement

10.
TROUBLESHOOTINg
PROBLEM: LOw OR NO OUTPUT VOLTAgE
REASON
Poor contact at terminal
Equipment being operated is drawing
too much power
Inverter is too hot (thermal shut down)
Fuse blows
Inverter may be defective
SOLUTION
Unplug and reinsert Power Inverter 140.
Use a higher capacity inverter or do not
use the device.
Allow inverter to cool. Check for adequate
ventilation. Reduce the load on the in-
verter to rated continuous power output.
A blown fuse is usually caused by reverse
polarity or a short circuit within the device
being operated. To replace:
• Disconnect the device immediately.
• Find the source of the problem and
repair it.
• Install a new 15-amp fuse. Do not
tighten the fuse cap too far; finger tight
is sufficient.
NOTE: Installing a fuse higher than 15-
amps may cause damage to the inverter.
Call 1-800-SEARS-64 for troubleshooting
assistance.