Dimmer Curve Setting:
1. Plug the fixture in and press the UP or DOWN buttons until "Menu Function" is displayed.
2. Press the ENTER button and then use the UP or DOWN buttons to scroll to "DimCurve" and press
ENTER.
3. There are 6 dimmer curve settings to choose from. Use the UP and DOWN buttons to scroll through
the different dimmer curve setting. See the Dimmer Curve Diagram Chart on page 14 to see the
different settings and their respective beginning and ending fade times.
4. Press the MODE button to exit and return to the main menu.
Display Set Up - In this submenu you are able to select what main display will show. In this sub-menu
you are able to designate the unit as the "Secondary" in Primary/Secondary mode.
1. Plug the fixture in and press the UP or DOWN buttons until "Menu Function" is displayed.
2. Press the ENTER button and press the UP or DOWN buttons to scroll to "Disp.Set" and press
ENTER.
3. Use the UP or DOWN buttons to find you desired setting and press ENTER.
4. Press the MODE button to exit and return to the main menu.
Software Update (USB Data) - This submenu is used for any future software updates. Check www.adj.
com and this units webpage for any software updates. Download the software update to a flash stick
and plug the flash stick into the Flash Drive slot located on the side of the unit.
Contact ADJ customer service for help when updating software.
Default Running Mode:
This is a default running mode. When this mode is activated all modes will return to their default settings.
1. Plug the fixture in and press the UP or DOWN buttons until "Menu Function" is displayed, and press
ENTER.
2. Press the UP or DOWN buttons to scroll to "DFSE" and press ENTER.
3. Press the UP and DOWN buttons to switch between "ON" or "OFF". To reset the unit to factory
settings select "ON" and press ENTER. Press the MODE button to exit the submenu with no changes.
Time Information - In this submenu you are able to check the current running time, total running time,
last time the running time was cleared, and clear the running time.
1. Plug the fixture in and press the UP or DOWN buttons until "Info" is displayed.
2. Press the ENTER button and press the UP or DOWN buttons until "TimeInfo" is displayed, and
press ENTER.
3. Use the UP or DOWN buttons to find the time information you would like to check. Press the ENTER
button to access your desired time information.
4. To clear the current running time, press UP or DOWN buttons until "TimerPin" is displayed, and
press ENTER. Use the UP or DOWN buttons to put in the "Clear" password "050", a press ENTER.
Use the UP or DOWN buttons to select "ON", and press ENTER. After doing this, unplug the fixture,
then plug it back in. The current running time should now be cleared.
5. Press the MODE button to exit and return to the "Infor" menu. Press MODE again to exit and return
to the main menu.