S Y S T E M M E N U
DMX Addressing:
Operating through a DMX controller gives the user the freedom to create their own programs tailored
to their own individual needs.
1. To run your fixture in DMX mode press the UP or DOWN buttons until "Set ADDR" is displayed.
Press the ENTER button and "Set ADDR XXX" will be displayed. "XXX" represents the current
displayed address.
2. Use the UP or DOWN buttons to find your desired DMX address and press ENTER to save the
address.
3. Please see page 14 for DMX values and traits.
4. After you have chosen your desired DMX Channel mode (see below) plug in the fixture via the XLR
connections to any standard DMX controller.
DMX Channel Mode:
The Encore FR150z has 6 DMX channel modes. This submenu will allow you to choose the DMX
channel mode you like the unit to operate under.
1. To select your desired DMX channel mode press the MODE button until "UserMode" is displayed.
Press the ENTER button and the current DMX channel mode will be displayed.
2. Use the UP or DOWN buttons to find your desired DMX channel mode and press ENTER to save
the mode.
3. Please see page 14 for your selected DMX mode values and traits.
4. After you have chosen your desired DMX Channel mode plug in the fixture via the XLR connections
to any standard DMX controller.
DMX State:
This mode can be used as a precaution mode, that in case the DMX signal is lost, the operating mode
chosen in the setup is the running mode the fixture will go into when the DMX signal is lost. You can
also set this as the operating mode you would like the unit to return to when power is applied.
1. Plug the fixture in and press the UP or DOWN buttons until "Menu Function" is displayed.
2. Press the ENTER button and then use the UP or DOWN buttons to scroll to "NO DMX" and press
ENTER. Use the UP or DOWN buttons to toggle between the two choices:
"Black" (Blackout) - If the DMX signal is lost or interrupted, the unit will automatically go into stand
by mode.
"Hold" (Last State) - If the DMX signal is lost or interrupted, the fixture will stay in the last DMX set
up.
3. Once you have found your desired mode, press ENTER, and press MODE to exit.
LCD Set Up - In this submenu you are able to adjust the settings for the LCD display. You can program
the display to blackout after 30 seconds, lock the buttons, or make the display flash.
1. Plug the fixture in and press the UP or DOWN buttons until "Menu Function" is displayed.
2. Press the ENTER button and press the UP or DOWN buttons to scroll to "LCD.Set" and press
ENTER.
3. Use the UP or DOWN buttons to make your desired adjustments in each submenu. Press the
ENTER button to move to the next adjustment submenu.
4. Press the MODE button to exit and return to the main menu.
Note: For the Key Lock setting, in addition to the usual On / Off options, this unit includes an "ON1"
option. In this mode, when the control panel is locked, the screen will display LOCKED *****. To unlock,
press UP, DOWN, UP, DOWN, ENTER in that order.
Unit Temperature - With this function, you can switch the temperature setting between Celsius or
Fahrenheit.
1. Plug the fixture in and press the UP or DOWN buttons until "Menu Function" is displayed.
2. Press the ENTER button and press the UP or DOWN buttons to scroll to "TEMP" and press ENTER.
3. Use the UP or DOWN buttons to switch between "Celsius" or "Fahren".
4. Press ENTER to confirm your selection or press the MODE button to exit and return to the main
menu.