Mobile Image Tables
Operator Manual
Made in the USA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Aspect 100-4T and is the answer not in the manual?

Questions and answers

Summary of Contents for idi Aspect 100-4T

  • Page 1 Aspect 100-4T and ISR Mobile Image Tables Operator Manual Made in the USA...
  • Page 2 Operator Manual OVERVIEW An Aspect 100-4T or Aspect ISR along with any accessories shall be referred to in this manual as “this equipment.” This manual is not intended as a substitute for certified training for the use of this equipment.
  • Page 3: Table Of Contents

    Aspect 100-4T and ISR Operator Manual Table of Contents SYMBOL IDENTIFICATION ..................... 5 INTENDED USE & ESSENTIAL PERFORMANCE ............8 SAFETY INSTRUCTIONS ....................8 SAFETY HAZARDS ......................9 EMC (Electromagnetic Compatibility) STATEMENT ........... 11 EMERGENCY STOP PUSHBUTTON ................12 SETUP INSTRUCTIONS ....................12 7.1.
  • Page 4 Aspect 100-4T and ISR Operator Manual 12. GENERAL CLEANING ..................... 27 13. MAINTENANCE, SERVICE & REPAIR ................ 28 13.1. RECOMMENDED PERIODIC PERFORMANCE CHECKS ......28 13.2. SERVICE & REPAIR STATEMENT ..............28 14. TROUBLESHOOTING ...................... 29 15. DISPOSAL OF COMPONENTS ..................32 16.
  • Page 5: Symbol Identification

    Aspect 100-4T and ISR Operator Manual SYMBOL IDENTIFICATION Attention! Consult accompanying documents. Failure to follow these instructions could cause serious personal injury or damage to equipment. Warning! Information or instructions shown near this symbol must be adhered to in order to prevent a potentially hazardous situation which if not avoided, could result in death, personal injury or damage to the equipment.
  • Page 6 Aspect 100-4T and ISR Operator Manual Protective Ground. This is the common tie point between the AC Electrical Power Cord Ground, Frame Ground, and Controller Ground. Patients must be loaded from the side of table. There is possible tilting or instability if patient is loaded onto the pedestal end of table or the imaging end of the table.
  • Page 7 Aspect 100-4T and ISR Operator Manual Elevate tabletop. Lower tabletop. Tilt tabletop’s imaging end up (Trendelenburg). Tilt tabletop’s imaging end down (Trendelenburg). Roll tabletop clockwise. Roll tabletop counterclockwise. Tabletop is centered from side to side. L100-2843 Rev. E www.imagediagnostics.com...
  • Page 8: Intended Use & Essential Performance

    Operator Manual INTENDED USE & ESSENTIAL PERFORMANCE The Aspect ISR & Aspect 100-4T are mobile imaging tables used by the medical industry for vascular surgery, endovascular procedures and interventional radiology. They are designed to be used in a professional healthcare environment in conjunction with “C-arm”...
  • Page 9: Safety Hazards

    Aspect 100-4T and ISR Operator Manual SAFETY HAZARDS Safety Hazard Level Potential Consequences with Use Indicates an imminently hazardous situation which, if not DANGER avoided, will result in death or serious injury. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
  • Page 10 Aspect 100-4T and ISR Operator Manual WARNING! Safely position and secure patient onto table. Do not exceed table weight capacity of 600 pounds (272kg). WARNING! Use of table extensions is only allowed with decreased table load. Table weight capacity reduced to 500 pounds (227kg) when using table extension.
  • Page 11: Emc (Electromagnetic Compatibility) Statement

    2. If this problem is not resolved, immediately remove power to the equipment by engaging the Emergency Stop Pushbutton as shown in section 6 of this manual. 3. Notify IDI customer service using the contact information in section 18 of this manual.
  • Page 12: Emergency Stop Pushbutton

    Aspect 100-4T and ISR Operator Manual EMERGENCY STOP PUSHBUTTON IMAGING END OF TABLETOP PEDESTAL END OF TABLETOP EMERGENCY STOP PUSHBUTTON ➢ The red Emergency Stop Pushbutton is located in the center of the base cover on the back of the table.
  • Page 13 Aspect 100-4T and ISR Operator Manual • When the table is not connected to AC power, the table will automatically switch to backup battery mode. The table should only be used under backup battery power temporarily for necessary function if the external power supply is lost.
  • Page 14: Instructions For Table Operation

    Aspect 100-4T and ISR Operator Manual INSTRUCTIONS FOR TABLE OPERATION 8.1. CASTER LOCKING AND UNLOCKING SETTINGS The rear casters can be configured in a locking setting which totally locks all motion of the rear casters and an unlocked setting which allows the rear casters to swivel freely.
  • Page 15: Power Indicator Light

    Stop Pushbutton is engaged. 8.3. TABLE MOTION CONTROLS All Aspect ISR & Aspect 100-4T tables are equipped with tabletop motion control boxes that allow users to move the tabletop in many different directions. PANHANDLE KNOB (PLACE PALM ON TOP OF KNOB,...
  • Page 16 Aspect 100-4T and ISR Operator Manual Continually pressing down on the Rocker Switch to the right of this symbol will raise the Tabletop vertically. Continually pressing down on the Rocker Switch to the right of this symbol will lower the Tabletop vertically.
  • Page 17 Aspect 100-4T and ISR Operator Manual Lifting the lip under the mushroom shaped Panhandle releases the brakes that stop all lateral and longitudinal motion of the Tabletop. Holding the ring up with fingertips allows the Tabletop to be manually repositioned. The Switch Lockout...
  • Page 18: Tabletop Motion Handset Controls

    Aspect 100-4T and ISR Operator Manual 8.4. TABLETOP MOTION HANDSET CONTROLS WARNING! The Handset Control is always active when connected to a powered-up table. WARNING! The Switch Lockout Pushbutton on the Motion Control Panhandle does not disable the Handset Control.
  • Page 19: Foot Actuated Motion Controls

    Operator Manual 8.5. FOOT ACTUATED MOTION CONTROLS 100-4T FOOT SWITCH CONTROL Foot Switch activated control motions for the Aspect 100-4T Tabletop are: elevate/lower and Trendelenburg down/up. (Safety hood helps avoid accidental motorized table movement from Foot Switch). • When the Trendelenburg Foot Pedal...
  • Page 20: Patient Preparation

    Aspect 100-4T and ISR Operator Manual PATIENT PREPARATION 9.1. Preparation for Patient Use • New Installation: This equipment will need to be properly cleaned before patient use as it will inevitably come into contact with contaminants during shipping, unpacking, storage, and installation.
  • Page 21: Preparation For Performing Cpr

    Aspect 100-4T and ISR Operator Manual 9.3. Preparation for Performing CPR • Return table to level position, retract tabletop to minimize overhang and lower table position to a comfortable height before performing CPR on a patient. 10. STANDARD ACCESSORIES 10.1.
  • Page 22: Patient Restraint Straps

    Aspect 100-4T and ISR Operator Manual 10.2. Patient Restraint Straps. WARNING! Strap configuration is recommended; however, patient restraint is a case-by-case condition. Please refer to facility’s policy on restraining a patient. The Patient Restraint Straps can be used in two different ways depending on where the strap is to be located along the length of the Tabletop.
  • Page 23: Add-On Accessories

    Aspect 100-4T and ISR Operator Manual 11. ADD-ON ACCESSORIES 11.1. Clamp-on Accessory Rail Fits on left or right side of table. 6” length. (European version with 10mm x 25mm metric rail is available). 11.2. Vascular Access Arm Board (VAB) One-piece, extra wide carbon fiber arm board for vascular access and fistula application procedures.
  • Page 24: Quick Release Rail Mount Arm Board (Requires Clamp-On Accessory Rail)

    Aspect 100-4T and ISR Operator Manual 11.3. Quick Release Rail Mount Arm Board (requires Clamp- on Accessory Rail) Radiolucent materials. Includes arm board, pad and restraint straps. (version for 10mm x 25mm metric rail size is available) 11.4. Arm Board, Shoulder Mount Carbon fiber base.
  • Page 25: Articulating Headrest Extension

    Aspect 100-4T and ISR Operator Manual 11.6. Articulating Headrest Extension WARNING! Use of table extensions is only allowed with decreased table load. Table weight capacity reduced to 500 pounds (227kg) when using table extension. Carbon fiber base extends Tabletop length 12”. Mounts to imaging end of Table onto 5”...
  • Page 26: Radiation Shield

    Aspect 100-4T and ISR Operator Manual 11.8. Radiation Shield Articulating with removable upper panel. Panels are lead-free. Can be used on either side of table. Mounts to both the accessory rail and the tabletop by clamp. 11.9. Anesthesia Screen Holder. (May require a pair of side rail clamps) Flexible Hoop.
  • Page 27: General Cleaning

    Aspect 100-4T and ISR Operator Manual 12. GENERAL CLEANING After each medical procedure, the table should be properly cleaned. Do not use harsh abrasives, solvents, sprays, or corrosive agents. Some accessories may come with individual cleaning instructions. APPROVED AND TESTED DISINFECTANT CLEANERS FOR TABLE: •...
  • Page 28: Maintenance, Service & Repair

    Aspect 100-4T and ISR Operator Manual 13. MAINTENANCE, SERVICE & REPAIR All maintenance procedures should be done by an experienced and qualified technician with demonstrated knowledge and skills (electrical and mechanical) in the service of medical equipment. ✓ This individual must have access to this manual and the proper tools.
  • Page 29: Troubleshooting

    Aspect 100-4T and ISR Operator Manual 14. TROUBLESHOOTING Note: The motion of the Tabletop is fully controlled by user interface with switches, buttons and a hand actuated brake release. In the event of a loss of these motions it is expected that the tabletop will remain stationary without any unwanted movement.
  • Page 30 Aspect 100-4T and ISR Operator Manual Problem/Symptom Possible Cause Remedy 5. Table does not 1. No Power. 1. Check electrical outlet. elevate. 2. Battery is depleted. 2. Connect to AC Power 3. Emergency Stop 3. Reset Emergency Stop Pushbutton. Pushbutton engaged.
  • Page 31 Aspect 100-4T and ISR Operator Manual Problem/Symptom Possible Cause Remedy 8. No response to 1. No Power. 1. Check electrical outlet. Tabletop Motion 2. Battery is depleted. 2. Connect to AC Power. Control Panhandle 3. Emergency Stop 3. Reset Emergency Stop Pushbutton.
  • Page 32: Disposal Of Components

    Aspect 100-4T and ISR Operator Manual 15. DISPOSAL OF COMPONENTS IDI medical tables are made up of mostly steel, copper and aluminum parts which are easily recycled. It is recommended that some components be disassembled before disposal for recycling. The table below lists components typically found in IDI products but varies with model and options.
  • Page 33: Product Data

    Aspect 100-4T and ISR Operator Manual 16. PRODUCT DATA Tabletop Low attenuation carbon fiber tabletop and pad. Tabletop surface 61cm x 155 cm (24 in x 84 in) standard. Imaging range along table length 172.7 cm (68 in)/203.2cm (80 in) with Headrest or Peripheral Extension.
  • Page 34: Specifications

    Aspect 100-4T and ISR Operator Manual 17. SPECIFICATIONS Mode of Operation ▪ For continuous use with short time loading. ▪ Duty Cycle: 10% (2 min on/18 min off). Type of Equipment: ▪ Class II Type B applied part (as defined by IEC 60601-1, UL 60601-1, EN 60601-1, CAN/CSA 601.1-M90, IEC 60601-2-46:1998.
  • Page 35 Aspect 100-4T and ISR Operator Manual Guidance and Manufacturer’s Declaration- Emissions, All Equipment and Systems: Table 1 This equipment is intended for use in the electromagnetic environment specified below. The customer or user of this equipment should ensure that it is used in such an environment.
  • Page 36 Aspect 100-4T and ISR Operator Manual Guidance and Manufacturer’s Declaration- Immunity, All Equipment and Systems: Table 2 This equipment is intended for use in the electromagnetic environment specified below. The customer or user of this equipment should ensure that it is used in such an environment.
  • Page 37 Aspect 100-4T and ISR Operator Manual Guidance and Manufacturer’s Declaration Emissions, Equipment and Systems that are NOT Life-Supporting Table 3 This equipment is intended for use in the electromagnetic environment specified below. The customer or user of this equipment should ensure that it is used in such an environment.
  • Page 38: Warranty And Contact Information

    7.3786 11.6666 11.6666 23.3333 18. WARRANTY AND CONTACT INFORMATION Warranty details for IDI Products can be obtained directly from Image Diagnostics, Inc. Image Diagnostics, Inc. 310 Authority Drive Fitchburg, MA 01420 USA Or call IDI at (978) 829-0009. L100-2843 Rev. E...