Before Start; Packaging; Electrostatic Discharge; Safe Working Practice - Eaton SONIX Vw2 Technical Manual

Termination unit
Table of Contents

Advertisement

2 Before start

2.1 Packaging

In the interest of preserving the environment, Eaton
aims to use recycled packaging wherever practical.
Due to the physical nature of our products, we provide
adequate packaging to protect the goods during transit.
Please ensure that once unpacked, checked and
installed that all packaging is disposed of or recycled in a
responsible manner.

2.2 Electrostatic discharge

The Sonix PA/GA system is largely constructed from
electronic printed circuit boards. These printed circuit
boards are sensitive to static electricity; ESD discharge
on to any of the Eaton products could cause permanent
and irreparable damage to the equipment. All such
PCB's are shipped to you in ESD protective bags for
transit. Prior to opening the transit bags please ensure
that you are wearing either an ESD, earthed wrist strap
or other suitable means of protection.

2.3 Safe working practice

Whilst working on or within the Sonix PA/GA system it
is our prime interest that you remain safe throughout.
During this work you may be exposed to potentially
hazardous voltages, currents, confined spaces and
potentially hazardous industrial environments. Prior to
undertaking any work please ensure relevant permits
and regulations are adhered to.

2.4 In the box

1x Sonix Vw2 unit
1x Technical Manual

2.5 Required tools

Small flat screw driver (0.4x2.0) – for DC power input
terminals
Flat screw driver (0.6x3.5) – for beacon power supply
and loops terminals
Vw2 Unit
L / +
N / -
E
L / +
N / -
E

3 Overview of the unit

3.1 Connectors and indicators

J1
J4
D20
Figure 1 – General, simplified view of Vw2 unit
Connector
J1
J6
J2
J3
J4
J5
F1, F2
D20
Earth
Table 1. On-board connectors and indicators

3.1.1 Weight and dimensions

Weight:
Dimensions
(H x W):

3.1.2 Power and utility

Voltage:
Current:
SONIX VW2 TECHNICAL MANUAL TM368 / A May 2022 www.eaton.com
Sonix Vw2 Technical Manual
J5
F1
F2
J3
FUNCTION
NOTES
Beacon Loop 1
Beacon Loop 2
3-way Phoenix Contact connectors
Beacon Input Supply
Vw2 Power Supply
2-way Phoenix Contact connector
Beacon Bus
Double-stacked RJ45 socket
Programming port
2x5 0.1'' pitch
10A slow blow fuses (replace with
Replaceable fuses
Mersen S218194 type fuse)
Power On LED
Green light when unit is powered
Earth bonding
M4x20 mm stud
700g
305 mm x 118 mm
48 V dc, recommended taken from Sonix
Pm10 unit
100 mA max consumption
J6
J2
7