Page 1
Sonix Pbx Technical Manual SONIX Record and Replay Unit...
Page 2
CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to...
Page 3
A 2Mx bus, used to communicate with SAS application Sync A 2Mx bus used to communicate with the second 2Mx unit when PA/GA system is confi gured as A&B, AB+ or N+1 system SONIX PBX TECHNICAL MANUAL TM372 / A June 2022 www.eaton.com...
2.7 Warnings that the contents are all correct and complete. Should this product reach you in an unsatisfactory condition please report this to Eaton to enable us to rectify and 2.7.1 Handling investigate the fault in a speedy manner. IEC 60417-6043 (2011-01) 2.2 Packaging...
Unit self-monitoring and fault reporting • Fault output • Remote configuration using Sonix software • * This requires special firmware loading into the unit, contact ote: Eaton for further information. SONIX PBX TECHNICAL MANUAL TM372 / A June 2022 www.eaton.com...
200 mA max consumption Pbx I/P Pbx I/P 0Vdc (-) Power connection 2 wire 48Vdc (+) Telephone I/F Primary Unit ID 1 Secondary Unit ID 2+ General fault connection SONIX PBX TECHNICAL MANUAL TM372 / A June 2022 www.eaton.com Pbx I/P Pbx I/P...
Blue units System control and Receives status data Table 3 – IO Bus description Pbx I/P Pbx I/P SONIX PBX TECHNICAL MANUAL TM372 / A June 2022 www.eaton.com 2 wire Telephone I/F Primary Unit ID 1 Secondary Unit ID 2+...
3.3.4 Power connections Input Keyline 2 The Sonix Pbx is powered via a 2-core 48 V dc input Table 5 – Message monitoring interface description on the rear of the unit. This input should be connected 0Vdc (-)
Not all states are relevant for each pair of LEDs and some indi- vidual LEDs may flash for specific functions (see the details below). 4.2.1 Power The power LED is a simple power active indicator. SONIX PBX TECHNICAL MANUAL TM372 / A June 2022 www.eaton.com...
Description 2-wire E&M operation not configured or available Solid green Set for 2-wire E&M operation Flashing options Front panel configuration (see section 4.8.5) Table 12 – 2-wire E&M LED description SONIX PBX TECHNICAL MANUAL TM372 / A June 2022 www.eaton.com...
(see Figure 8) and prompt the user to leave a message to be broadcast using the default zone list set by the unit’s configuration. SONIX PBX TECHNICAL MANUAL TM372 / A June 2022 www.eaton.com...
Figure 9 – Zoning flow chart ote: The announcement if loaded will precede the call answered tone (a series of bleeps) relayed over the telephone at the start of zoning. SONIX PBX TECHNICAL MANUAL TM372 / A June 2022 www.eaton.com...
Figure 10 – Messages recording flow chart ote: The announcement if loaded will precede the record tone (a single bleep) relayed over the telephone at the start of recording.. SONIX PBX TECHNICAL MANUAL TM372 / A June 2022 www.eaton.com...
Therefore, recorded messages will automatically enter Figure 11 – Message playback flow chart ote: A holding tone (a short bleep every sec) will be relayed over the telephone if the message has been queued. SONIX PBX TECHNICAL MANUAL TM372 / A June 2022 www.eaton.com...
Some faults may need a fault reset applied to the unit either and is turned clockwise to increase the sensitivity of the from the 2Mx or via the fault panel button. VOX circuit. SONIX PBX TECHNICAL MANUAL TM372 / A June 2022 www.eaton.com...
5.3 Firmware customisation Please contact your Eaton representative if the custom/ special functionality or operation of the Sonix system and/or Pbx is required. SONIX PBX TECHNICAL MANUAL TM372 / A June 2022 www.eaton.com...
Page 20
Warning: Remove power before disconnecting any cabling or removing the unit from the rack. ote: Notice: Do not use sharp objects, water, aggressive cleaning agents or solvent to clean the unit SONIX PBX TECHNICAL MANUAL TM372 / A June 2022 www.eaton.com...
Page 21
Sonix Pbx Technical Manual SONIX PBX TECHNICAL MANUAL TM372 / A June 2022 www.eaton.com...
Page 22
All specifications, dimensions, weights and tolerances are nominal (typical) T: +44 (0) 1623 444 400 Printed in UK www.crouse-hinds.com/hac Publication No.TM372 / A and Eaton reserve the right to vary all data without prior notice. No liability is accepted for any consequence of use. MEDCSales@Eaton.com June 2022...
Need help?
Do you have a question about the SONIX Pbx and is the answer not in the manual?
Questions and answers