Setup
NOTICE
Any debris or dirt accidentally introduced into the res-
ervoir should be removed immediately. Do not allow
the pump to operate until any debris or dirt are
removed.
Operating the pump with debris or dirt in the reservoir,
may damage the pump, down stream equipment, and
bearings.
7. Clean the threads on the reservoir and the lid.
8. Replace the lid on the reservoir, turning clockwise
(approximately 1 3/4 turns).
9. Reconnect the power to the equipment.
Models With a Follower Plate
1. Connect the fill hose to the inlet fitting (F
2. For higher viscosity fluids, start the pump to rotate
the stirring paddle during filling to prevent air
pockets from forming in the grease. Do not exceed
a 30 minute run time.
For models using an external controller, start the
pump operation per your controller specifications.
22
3. Fill the reservoir with grease until the seal of the
follower plate breaches the vent hole and the
majority of air is expelled from the reservoir.
NOTE: The vent port, located in rear of reservoir,
should not be used as an overfill port/indicator.
Vent Hole
. 19).
IG
F
. 21
IG
4. Turn off the air supply (H) to the refill pump (F).
5. Remove the fill hose.