Kenmore 795.71312.311 Service Manual page 50

Bottom freezer refrigerator
Table of Contents

Advertisement

https://appliancetechmanuals.com
11-6 REFRIGERATION CYCLE
Troubleshooting Chart
CAUSE
PARTIAL
LEAKAGE
COMPLETE
LEAKAGE
PARTIAL
CLOG
WHOLE
CLOG
MOISTURE CLOG
COMP-
RESSION
NO COMP-
RESSION
12-6-1 Cleaning
There is no need for routine condenser cleaning in normal Home operating environments. If the environment is
particularly greasy or dusty, or there is significant pet traffic in the home, the condenser should be cleaned
every 2 to 3 months to ensure maximum efficiency.
If you need to clean the condenser:
Remove the mechanical cover.
Use a vacuum cleaner with a soft brush to clean the grille, the open areas behind the grille and the front
surface area of the condenser.
Replace the mechanical cover.
STATE OF
STATE OF THE
THE UNIT
EVAPORATOR
Freezer
Low flowing sound of
compartment and
Refrigerant is heard
Refrigerator don't
and frost forms in
cool normally.
Evaporator inlet only.
Freezer
Flowing sound of
compartment and
refrigerant is not
Refrigerator don't
heard and frost isn't
cool normally.
formed.
Freezer
Flowing sound of
compartment and
refrigerant is heard
Refrigerator don't
and frost forms in
cool normally.
Evaporator inlet only.
Freezer
Flowing sound of
compartment and
refrigerant is not
Refrigerator don't
heard and frost isn't
cool.
formed.
Cooling operation
Flowing sound of
stops periodically.
refrigerant is not
heard and frost melts.
Freezer and
Low flowing sound of
Refrigerator don't
refrigerant is heard
cool.
and frost forms in
Evaporator inlet only.
No compressing
Flowing sound of
operation.
refrigerant is not
heard and there is
no frost.
TEMPERATURE
OF THE
COMPRESSOR
A little higher than
• Refrigerant level is low due
ambient
to a leak.
temperature.
• Normal cooling is possible by
restoring the normal amount
of refrigerant and repairing
the leak.
Equal to ambient
• No discharging of
temperature.
Refrigerant.
• Normal cooling is possible by
restoring the normal amount
of refrigerant and repairing
the leak.
A little higher than
• Normal discharging of the
ambient
refrigerant.
temperature.
• The capillary tube is faulty.
Equal to ambient
• Normal discharging of the
temperature.
Refrigerant.
Lower than ambient
• Cooling operation restarts
temperature.
when heating the inlet of the
capillary tube.
A little higher than
• Low pressure at high side of
ambient
compressor due to low
temperature.
refrigerant level.
Equal to ambient
• No pressure in the high
temperature.
pressure part of the
compressor.
REMARKS