Kenmore 795.71312.311 Service Manual page 18

Bottom freezer refrigerator
Table of Contents

Advertisement

https://appliancetechmanuals.com
7-3 Icing Sensor Error (IS E)
No
1
Check for loose connection in CON8.
<Drawer Model>
2
1-. Unplug connector from CON8.
2-. Check resistance between
wires Red to Orange.
<Swing Model>
1-. Unplug connector from CON4.
2-. Check resistance between
wires Red to Orange.
Checking flow
<CON8>
<CON4>
Result & SVC Action
Result
Short
Change the sensor
0 ?
Open
Replace the refrigerator
OFF
Check the Temp and
Other
Normal
resistance (Table-1)
<Temperature table-1>
Temperature
40.5 ~ 38.5 ㏀
-22°F / -30°C
30.5 ~ 28.5 ㏀
-13°F / -25°C
-4°F / -20°C
17.5 ~ 16.5 ㏀
5°F / -15°C
13.5 ~ 12.5 ㏀
14°F / -10°C
23°F / -5°C
32°F / 0°C
? The sensor is determined by
the temperature.
For example, 23㏀ indicates -4°F.
SVC Action
Result
23 ~ 21.5 ㏀
10.5 ~ 9.5 ㏀
8 ~7.5 ㏀